| Authors: |
Mooser, Anne1 (AUTHOR), Johnson, Gregory1,2 (AUTHOR), McDonnell, Conor1,2 (AUTHOR), Matava, Clyde1,2 (AUTHOR) clyde.matava@sickkids.ca |
| Source: |
Journal of Medical Systems. 3/27/2026, Vol. 50 Issue 1, p1-5. 5p. |
| Subjects: |
Medication error prevention, Medical information storage & retrieval systems, Cross-sectional method, Work, Cronbach's alpha, Diffusion of innovations, Patient safety, Questionnaires, Research evaluation, Anesthesiologists, Tertiary care, Children's hospitals, Physicians' attitudes, Descriptive statistics, Structural equation modeling, Intravenous therapy, Drug infusion pumps, Professions, Conceptual structures, System integration, Medical records, Comparative studies, Sociodemographic factors, Quality assurance, Operating rooms, Experiential learning, Anesthesia |
| Abstract: |
The integration of intravenous (IV) smart pumps with electronic health records (EHR) has been shown to reduce documentation errors and improve safety in nursing practice. However, there is limited information regarding the acceptance of this technology among anesthesiologists. This study aimed to evaluate the acceptance and adoption of IV smart pump integration with an Anesthesia Information Management System (AIMS) at a tertiary pediatric hospital. We conducted a cross-sectional survey six weeks following the implementation of IV smart pump integration. The project was approved as a Quality Improvement initiative. The survey was distributed to 112 anesthesia department members. We employed the Unified Theory of Acceptance and Use of Technology (UTAUT) to assess user acceptance, examining constructs such as Performance Expectancy, Effort Expectancy, Social Influence, and Facilitating Conditions. Structural equation modeling (SEM) was used to analyze the relationships between these constructs and Behavioral Intention. Forty-two individuals (38.1%) completed the survey. Adoption was widespread, with respondents utilizing smart pump integration for a median of 76.5% of eligible medications. While 48% of respondents reported satisfaction, 26% were unsatisfied, primarily citing difficulties with troubleshooting. Structural equation modeling revealed that Performance Expectancy was the strongest predictor of Behavioral Intention (path coefficient 0.60), followed by Facilitating Conditions (0.21). Age positively influenced Social Influence (0.25) but negatively affected Performance Expectancy (-0.15). Anesthesiologists demonstrated a high rate of adoption of IV smart pump integration shortly after implementation. Perceived usefulness was the primary driver of the intention to use the system. Given the single-center nature of this study and the limited response rate, these results should be considered hypothesis-generating. Strategies to optimize future adoption should focus on demonstrating clinical utility and providing targeted training on troubleshooting. [ABSTRACT FROM AUTHOR] |
|
Copyright of Journal of Medical Systems is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |