Acceptance and Adoption of Intravenous Smart Pump Integration to Anesthesia Information Management System by Anesthesiologists: A Single Centre Study.

Saved in:
Bibliographic Details
Title: Acceptance and Adoption of Intravenous Smart Pump Integration to Anesthesia Information Management System by Anesthesiologists: A Single Centre Study.
Authors: Mooser, Anne1 (AUTHOR), Johnson, Gregory1,2 (AUTHOR), McDonnell, Conor1,2 (AUTHOR), Matava, Clyde1,2 (AUTHOR) clyde.matava@sickkids.ca
Source: Journal of Medical Systems. 3/27/2026, Vol. 50 Issue 1, p1-5. 5p.
Subjects: Medication error prevention, Medical information storage & retrieval systems, Cross-sectional method, Work, Cronbach's alpha, Diffusion of innovations, Patient safety, Questionnaires, Research evaluation, Anesthesiologists, Tertiary care, Children's hospitals, Physicians' attitudes, Descriptive statistics, Structural equation modeling, Intravenous therapy, Drug infusion pumps, Professions, Conceptual structures, System integration, Medical records, Comparative studies, Sociodemographic factors, Quality assurance, Operating rooms, Experiential learning, Anesthesia
Abstract: The integration of intravenous (IV) smart pumps with electronic health records (EHR) has been shown to reduce documentation errors and improve safety in nursing practice. However, there is limited information regarding the acceptance of this technology among anesthesiologists. This study aimed to evaluate the acceptance and adoption of IV smart pump integration with an Anesthesia Information Management System (AIMS) at a tertiary pediatric hospital. We conducted a cross-sectional survey six weeks following the implementation of IV smart pump integration. The project was approved as a Quality Improvement initiative. The survey was distributed to 112 anesthesia department members. We employed the Unified Theory of Acceptance and Use of Technology (UTAUT) to assess user acceptance, examining constructs such as Performance Expectancy, Effort Expectancy, Social Influence, and Facilitating Conditions. Structural equation modeling (SEM) was used to analyze the relationships between these constructs and Behavioral Intention. Forty-two individuals (38.1%) completed the survey. Adoption was widespread, with respondents utilizing smart pump integration for a median of 76.5% of eligible medications. While 48% of respondents reported satisfaction, 26% were unsatisfied, primarily citing difficulties with troubleshooting. Structural equation modeling revealed that Performance Expectancy was the strongest predictor of Behavioral Intention (path coefficient 0.60), followed by Facilitating Conditions (0.21). Age positively influenced Social Influence (0.25) but negatively affected Performance Expectancy (-0.15). Anesthesiologists demonstrated a high rate of adoption of IV smart pump integration shortly after implementation. Perceived usefulness was the primary driver of the intention to use the system. Given the single-center nature of this study and the limited response rate, these results should be considered hypothesis-generating. Strategies to optimize future adoption should focus on demonstrating clinical utility and providing targeted training on troubleshooting. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Medical Systems is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 192561454
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Acceptance and Adoption of Intravenous Smart Pump Integration to Anesthesia Information Management System by Anesthesiologists: A Single Centre Study.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Mooser%2C+Anne%22">Mooser, Anne</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Johnson%2C+Gregory%22">Johnson, Gregory</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22McDonnell%2C+Conor%22">McDonnell, Conor</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Matava%2C+Clyde%22">Matava, Clyde</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> clyde.matava@sickkids.ca</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Journal+of+Medical+Systems%22">Journal of Medical Systems</searchLink>. 3/27/2026, Vol. 50 Issue 1, p1-5. 5p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Medication+error+prevention%22">Medication error prevention</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+information+storage+%26+retrieval+systems%22">Medical information storage & retrieval systems</searchLink><br /><searchLink fieldCode="DE" term="%22Cross-sectional+method%22">Cross-sectional method</searchLink><br /><searchLink fieldCode="DE" term="%22Work%22">Work</searchLink><br /><searchLink fieldCode="DE" term="%22Cronbach's+alpha%22">Cronbach's alpha</searchLink><br /><searchLink fieldCode="DE" term="%22Diffusion+of+innovations%22">Diffusion of innovations</searchLink><br /><searchLink fieldCode="DE" term="%22Patient+safety%22">Patient safety</searchLink><br /><searchLink fieldCode="DE" term="%22Questionnaires%22">Questionnaires</searchLink><br /><searchLink fieldCode="DE" term="%22Research+evaluation%22">Research evaluation</searchLink><br /><searchLink fieldCode="DE" term="%22Anesthesiologists%22">Anesthesiologists</searchLink><br /><searchLink fieldCode="DE" term="%22Tertiary+care%22">Tertiary care</searchLink><br /><searchLink fieldCode="DE" term="%22Children's+hospitals%22">Children's hospitals</searchLink><br /><searchLink fieldCode="DE" term="%22Physicians'+attitudes%22">Physicians' attitudes</searchLink><br /><searchLink fieldCode="DE" term="%22Descriptive+statistics%22">Descriptive statistics</searchLink><br /><searchLink fieldCode="DE" term="%22Structural+equation+modeling%22">Structural equation modeling</searchLink><br /><searchLink fieldCode="DE" term="%22Intravenous+therapy%22">Intravenous therapy</searchLink><br /><searchLink fieldCode="DE" term="%22Drug+infusion+pumps%22">Drug infusion pumps</searchLink><br /><searchLink fieldCode="DE" term="%22Professions%22">Professions</searchLink><br /><searchLink fieldCode="DE" term="%22Conceptual+structures%22">Conceptual structures</searchLink><br /><searchLink fieldCode="DE" term="%22System+integration%22">System integration</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+records%22">Medical records</searchLink><br /><searchLink fieldCode="DE" term="%22Comparative+studies%22">Comparative studies</searchLink><br /><searchLink fieldCode="DE" term="%22Sociodemographic+factors%22">Sociodemographic factors</searchLink><br /><searchLink fieldCode="DE" term="%22Quality+assurance%22">Quality assurance</searchLink><br /><searchLink fieldCode="DE" term="%22Operating+rooms%22">Operating rooms</searchLink><br /><searchLink fieldCode="DE" term="%22Experiential+learning%22">Experiential learning</searchLink><br /><searchLink fieldCode="DE" term="%22Anesthesia%22">Anesthesia</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: The integration of intravenous (IV) smart pumps with electronic health records (EHR) has been shown to reduce documentation errors and improve safety in nursing practice. However, there is limited information regarding the acceptance of this technology among anesthesiologists. This study aimed to evaluate the acceptance and adoption of IV smart pump integration with an Anesthesia Information Management System (AIMS) at a tertiary pediatric hospital. We conducted a cross-sectional survey six weeks following the implementation of IV smart pump integration. The project was approved as a Quality Improvement initiative. The survey was distributed to 112 anesthesia department members. We employed the Unified Theory of Acceptance and Use of Technology (UTAUT) to assess user acceptance, examining constructs such as Performance Expectancy, Effort Expectancy, Social Influence, and Facilitating Conditions. Structural equation modeling (SEM) was used to analyze the relationships between these constructs and Behavioral Intention. Forty-two individuals (38.1%) completed the survey. Adoption was widespread, with respondents utilizing smart pump integration for a median of 76.5% of eligible medications. While 48% of respondents reported satisfaction, 26% were unsatisfied, primarily citing difficulties with troubleshooting. Structural equation modeling revealed that Performance Expectancy was the strongest predictor of Behavioral Intention (path coefficient 0.60), followed by Facilitating Conditions (0.21). Age positively influenced Social Influence (0.25) but negatively affected Performance Expectancy (-0.15). Anesthesiologists demonstrated a high rate of adoption of IV smart pump integration shortly after implementation. Perceived usefulness was the primary driver of the intention to use the system. Given the single-center nature of this study and the limited response rate, these results should be considered hypothesis-generating. Strategies to optimize future adoption should focus on demonstrating clinical utility and providing targeted training on troubleshooting. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Journal of Medical Systems is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=192561454
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1007/s10916-026-02356-7
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 5
        StartPage: 1
    Subjects:
      – SubjectFull: Medication error prevention
        Type: general
      – SubjectFull: Medical information storage & retrieval systems
        Type: general
      – SubjectFull: Cross-sectional method
        Type: general
      – SubjectFull: Work
        Type: general
      – SubjectFull: Cronbach's alpha
        Type: general
      – SubjectFull: Diffusion of innovations
        Type: general
      – SubjectFull: Patient safety
        Type: general
      – SubjectFull: Questionnaires
        Type: general
      – SubjectFull: Research evaluation
        Type: general
      – SubjectFull: Anesthesiologists
        Type: general
      – SubjectFull: Tertiary care
        Type: general
      – SubjectFull: Children's hospitals
        Type: general
      – SubjectFull: Physicians' attitudes
        Type: general
      – SubjectFull: Descriptive statistics
        Type: general
      – SubjectFull: Structural equation modeling
        Type: general
      – SubjectFull: Intravenous therapy
        Type: general
      – SubjectFull: Drug infusion pumps
        Type: general
      – SubjectFull: Professions
        Type: general
      – SubjectFull: Conceptual structures
        Type: general
      – SubjectFull: System integration
        Type: general
      – SubjectFull: Medical records
        Type: general
      – SubjectFull: Comparative studies
        Type: general
      – SubjectFull: Sociodemographic factors
        Type: general
      – SubjectFull: Quality assurance
        Type: general
      – SubjectFull: Operating rooms
        Type: general
      – SubjectFull: Experiential learning
        Type: general
      – SubjectFull: Anesthesia
        Type: general
    Titles:
      – TitleFull: Acceptance and Adoption of Intravenous Smart Pump Integration to Anesthesia Information Management System by Anesthesiologists: A Single Centre Study.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Mooser, Anne
      – PersonEntity:
          Name:
            NameFull: Johnson, Gregory
      – PersonEntity:
          Name:
            NameFull: McDonnell, Conor
      – PersonEntity:
          Name:
            NameFull: Matava, Clyde
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 27
              M: 03
              Text: 3/27/2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 01485598
          Numbering:
            – Type: volume
              Value: 50
            – Type: issue
              Value: 1
          Titles:
            – TitleFull: Journal of Medical Systems
              Type: main
ResultId 1