| Subjects: | Medication error prevention, Medical information storage & retrieval systems, Cross-sectional method, Work, Cronbach's alpha, Diffusion of innovations, Patient safety, Questionnaires, Research evaluation, Anesthesiologists, Tertiary care, Children's hospitals, Physicians' attitudes, Descriptive statistics, Structural equation modeling, Intravenous therapy, Drug infusion pumps, Professions, Conceptual structures, System integration, Medical records, Comparative studies, Sociodemographic factors, Quality assurance, Operating rooms, Experiential learning, Anesthesia |
| Abstract: | The integration of intravenous (IV) smart pumps with electronic health records (EHR) has been shown to reduce documentation errors and improve safety in nursing practice. However, there is limited information regarding the acceptance of this technology among anesthesiologists. This study aimed to evaluate the acceptance and adoption of IV smart pump integration with an Anesthesia Information Management System (AIMS) at a tertiary pediatric hospital. We conducted a cross-sectional survey six weeks following the implementation of IV smart pump integration. The project was approved as a Quality Improvement initiative. The survey was distributed to 112 anesthesia department members. We employed the Unified Theory of Acceptance and Use of Technology (UTAUT) to assess user acceptance, examining constructs such as Performance Expectancy, Effort Expectancy, Social Influence, and Facilitating Conditions. Structural equation modeling (SEM) was used to analyze the relationships between these constructs and Behavioral Intention. Forty-two individuals (38.1%) completed the survey. Adoption was widespread, with respondents utilizing smart pump integration for a median of 76.5% of eligible medications. While 48% of respondents reported satisfaction, 26% were unsatisfied, primarily citing difficulties with troubleshooting. Structural equation modeling revealed that Performance Expectancy was the strongest predictor of Behavioral Intention (path coefficient 0.60), followed by Facilitating Conditions (0.21). Age positively influenced Social Influence (0.25) but negatively affected Performance Expectancy (-0.15). Anesthesiologists demonstrated a high rate of adoption of IV smart pump integration shortly after implementation. Perceived usefulness was the primary driver of the intention to use the system. Given the single-center nature of this study and the limited response rate, these results should be considered hypothesis-generating. Strategies to optimize future adoption should focus on demonstrating clinical utility and providing targeted training on troubleshooting. [ABSTRACT FROM AUTHOR] |
| Copyright of Journal of Medical Systems is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 192561454 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Acceptance and Adoption of Intravenous Smart Pump Integration to Anesthesia Information Management System by Anesthesiologists: A Single Centre Study. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Mooser%2C+Anne%22">Mooser, Anne</searchLink><relatesTo>1</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Johnson%2C+Gregory%22">Johnson, Gregory</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22McDonnell%2C+Conor%22">McDonnell, Conor</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<br /><searchLink fieldCode="AR" term="%22Matava%2C+Clyde%22">Matava, Clyde</searchLink><relatesTo>1,2</relatesTo> (AUTHOR)<i> clyde.matava@sickkids.ca</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Journal+of+Medical+Systems%22">Journal of Medical Systems</searchLink>. 3/27/2026, Vol. 50 Issue 1, p1-5. 5p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Medication+error+prevention%22">Medication error prevention</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+information+storage+%26+retrieval+systems%22">Medical information storage & retrieval systems</searchLink><br /><searchLink fieldCode="DE" term="%22Cross-sectional+method%22">Cross-sectional method</searchLink><br /><searchLink fieldCode="DE" term="%22Work%22">Work</searchLink><br /><searchLink fieldCode="DE" term="%22Cronbach's+alpha%22">Cronbach's alpha</searchLink><br /><searchLink fieldCode="DE" term="%22Diffusion+of+innovations%22">Diffusion of innovations</searchLink><br /><searchLink fieldCode="DE" term="%22Patient+safety%22">Patient safety</searchLink><br /><searchLink fieldCode="DE" term="%22Questionnaires%22">Questionnaires</searchLink><br /><searchLink fieldCode="DE" term="%22Research+evaluation%22">Research evaluation</searchLink><br /><searchLink fieldCode="DE" term="%22Anesthesiologists%22">Anesthesiologists</searchLink><br /><searchLink fieldCode="DE" term="%22Tertiary+care%22">Tertiary care</searchLink><br /><searchLink fieldCode="DE" term="%22Children's+hospitals%22">Children's hospitals</searchLink><br /><searchLink fieldCode="DE" term="%22Physicians'+attitudes%22">Physicians' attitudes</searchLink><br /><searchLink fieldCode="DE" term="%22Descriptive+statistics%22">Descriptive statistics</searchLink><br /><searchLink fieldCode="DE" term="%22Structural+equation+modeling%22">Structural equation modeling</searchLink><br /><searchLink fieldCode="DE" term="%22Intravenous+therapy%22">Intravenous therapy</searchLink><br /><searchLink fieldCode="DE" term="%22Drug+infusion+pumps%22">Drug infusion pumps</searchLink><br /><searchLink fieldCode="DE" term="%22Professions%22">Professions</searchLink><br /><searchLink fieldCode="DE" term="%22Conceptual+structures%22">Conceptual structures</searchLink><br /><searchLink fieldCode="DE" term="%22System+integration%22">System integration</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+records%22">Medical records</searchLink><br /><searchLink fieldCode="DE" term="%22Comparative+studies%22">Comparative studies</searchLink><br /><searchLink fieldCode="DE" term="%22Sociodemographic+factors%22">Sociodemographic factors</searchLink><br /><searchLink fieldCode="DE" term="%22Quality+assurance%22">Quality assurance</searchLink><br /><searchLink fieldCode="DE" term="%22Operating+rooms%22">Operating rooms</searchLink><br /><searchLink fieldCode="DE" term="%22Experiential+learning%22">Experiential learning</searchLink><br /><searchLink fieldCode="DE" term="%22Anesthesia%22">Anesthesia</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: The integration of intravenous (IV) smart pumps with electronic health records (EHR) has been shown to reduce documentation errors and improve safety in nursing practice. However, there is limited information regarding the acceptance of this technology among anesthesiologists. This study aimed to evaluate the acceptance and adoption of IV smart pump integration with an Anesthesia Information Management System (AIMS) at a tertiary pediatric hospital. We conducted a cross-sectional survey six weeks following the implementation of IV smart pump integration. The project was approved as a Quality Improvement initiative. The survey was distributed to 112 anesthesia department members. We employed the Unified Theory of Acceptance and Use of Technology (UTAUT) to assess user acceptance, examining constructs such as Performance Expectancy, Effort Expectancy, Social Influence, and Facilitating Conditions. Structural equation modeling (SEM) was used to analyze the relationships between these constructs and Behavioral Intention. Forty-two individuals (38.1%) completed the survey. Adoption was widespread, with respondents utilizing smart pump integration for a median of 76.5% of eligible medications. While 48% of respondents reported satisfaction, 26% were unsatisfied, primarily citing difficulties with troubleshooting. Structural equation modeling revealed that Performance Expectancy was the strongest predictor of Behavioral Intention (path coefficient 0.60), followed by Facilitating Conditions (0.21). Age positively influenced Social Influence (0.25) but negatively affected Performance Expectancy (-0.15). Anesthesiologists demonstrated a high rate of adoption of IV smart pump integration shortly after implementation. Perceived usefulness was the primary driver of the intention to use the system. Given the single-center nature of this study and the limited response rate, these results should be considered hypothesis-generating. Strategies to optimize future adoption should focus on demonstrating clinical utility and providing targeted training on troubleshooting. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Journal of Medical Systems is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=192561454 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1007/s10916-026-02356-7 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 5 StartPage: 1 Subjects: – SubjectFull: Medication error prevention Type: general – SubjectFull: Medical information storage & retrieval systems Type: general – SubjectFull: Cross-sectional method Type: general – SubjectFull: Work Type: general – SubjectFull: Cronbach's alpha Type: general – SubjectFull: Diffusion of innovations Type: general – SubjectFull: Patient safety Type: general – SubjectFull: Questionnaires Type: general – SubjectFull: Research evaluation Type: general – SubjectFull: Anesthesiologists Type: general – SubjectFull: Tertiary care Type: general – SubjectFull: Children's hospitals Type: general – SubjectFull: Physicians' attitudes Type: general – SubjectFull: Descriptive statistics Type: general – SubjectFull: Structural equation modeling Type: general – SubjectFull: Intravenous therapy Type: general – SubjectFull: Drug infusion pumps Type: general – SubjectFull: Professions Type: general – SubjectFull: Conceptual structures Type: general – SubjectFull: System integration Type: general – SubjectFull: Medical records Type: general – SubjectFull: Comparative studies Type: general – SubjectFull: Sociodemographic factors Type: general – SubjectFull: Quality assurance Type: general – SubjectFull: Operating rooms Type: general – SubjectFull: Experiential learning Type: general – SubjectFull: Anesthesia Type: general Titles: – TitleFull: Acceptance and Adoption of Intravenous Smart Pump Integration to Anesthesia Information Management System by Anesthesiologists: A Single Centre Study. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Mooser, Anne – PersonEntity: Name: NameFull: Johnson, Gregory – PersonEntity: Name: NameFull: McDonnell, Conor – PersonEntity: Name: NameFull: Matava, Clyde IsPartOfRelationships: – BibEntity: Dates: – D: 27 M: 03 Text: 3/27/2026 Type: published Y: 2026 Identifiers: – Type: issn-print Value: 01485598 Numbering: – Type: volume Value: 50 – Type: issue Value: 1 Titles: – TitleFull: Journal of Medical Systems Type: main |
| ResultId | 1 |