Inerter-based tuned mass dampers for response control of multi-degree-of-freedom structures subjected to wind and earthquake excitations.

Saved in:
Bibliographic Details
Title: Inerter-based tuned mass dampers for response control of multi-degree-of-freedom structures subjected to wind and earthquake excitations.
Authors: Das, Anupam1 (AUTHOR) anupam.besus11@gmail.com, Banerjee, Arnab1 (AUTHOR), Sahoo, Dipti Ranjan1 (AUTHOR), Matsagar, Vasant1 (AUTHOR)
Source: Structure & Infrastructure Engineering: Maintenance, Management, Life-Cycle Design & Performance. Apr2026, Vol. 22 Issue 4, p624-637. 14p.
Subjects: Tuned mass dampers, Structural control (Engineering), Wind pressure, Single-degree-of-freedom systems, Inertia (Mechanics), Earthquakes, Mathematical optimization
Abstract: The present work explores the utilization of the tuned mass damper-inerter (TMDI) in controlling the structural response subjected to wind and earthquake excitations. An example of a 25-storey reinforced concrete building is taken up. The equations of motion of the structure-TMDI combined system are established by assuming the building behaves as a shear-building with multiple degrees of freedom. These equations are solved using Newmark's time integration method. The objective functions are the wind- and earthquake-induced structural response quantities, such as the maximum inter-storey drift ratio (MIDR) and peak floor acceleration (PFA). The prime contribution of this study is the inclusion of statistical measures such as the mean, 85th, and 95th percentiles for these quantities. A genetic algorithm-based multi-objective optimization is performed to estimate the optimum TMDI parameters. Based on the outcomes of this study, it can be recommended that the TMDI be optimized to perform well under the 95th percentile for MIDR and PFA in effectively reducing the peak structural responses. Frequency domain analysis results demonstrate TMDI's multiple-mode controlling capability. The energy comparison plots of the uncontrolled and controlled structures prove the effectiveness of the optimum TMDI in providing enough damping and ensuring structural stability. [ABSTRACT FROM AUTHOR]
Copyright of Structure & Infrastructure Engineering: Maintenance, Management, Life-Cycle Design & Performance is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:The present work explores the utilization of the tuned mass damper-inerter (TMDI) in controlling the structural response subjected to wind and earthquake excitations. An example of a 25-storey reinforced concrete building is taken up. The equations of motion of the structure-TMDI combined system are established by assuming the building behaves as a shear-building with multiple degrees of freedom. These equations are solved using Newmark's time integration method. The objective functions are the wind- and earthquake-induced structural response quantities, such as the maximum inter-storey drift ratio (MIDR) and peak floor acceleration (PFA). The prime contribution of this study is the inclusion of statistical measures such as the mean, 85th, and 95th percentiles for these quantities. A genetic algorithm-based multi-objective optimization is performed to estimate the optimum TMDI parameters. Based on the outcomes of this study, it can be recommended that the TMDI be optimized to perform well under the 95th percentile for MIDR and PFA in effectively reducing the peak structural responses. Frequency domain analysis results demonstrate TMDI's multiple-mode controlling capability. The energy comparison plots of the uncontrolled and controlled structures prove the effectiveness of the optimum TMDI in providing enough damping and ensuring structural stability. [ABSTRACT FROM AUTHOR]
ISSN:15732479