Evaluating the selection process for optical sensor system configurations used in surface metrology applications.

Saved in:
Bibliographic Details
Title: Evaluating the selection process for optical sensor system configurations used in surface metrology applications.
Authors: Sokolov, Alexandr M.1 (AUTHOR) asokolov@astate.edu, Simpson, Travis1 (AUTHOR) travis.simpson@smail.astate.edu, Ahmed, Ifaz1 (AUTHOR) Ifaz.ahmed@smail.astate.edu
Source: Measurement (02632241). Jun2026, Vol. 280, pN.PAG-N.PAG. 1p.
Subjects: Interferometry, Ball grid array technology, Confocal microscopy, Optical sensors, Surface roughness measurement, Substrates (Materials science), Microfabrication
Abstract: • A comparative analysis of the performance of three surface metrology systems is conducted. • The attributes of the silicon wafer, the Ball Grid Array (BGA), and the substrate-bonded die are measured. • Different measurement systems are suitable for different cases. • White Light Interferometry performs best but requires higher measurement times. • A weighted decision matrix identifies optimal system configurations. Surface metrology is very crucial for precision manufacturing processes, especially in the semiconductor industry, to measure different characteristics of silicon wafers or a Ball Grid Array (BGA). Various surface metrology approaches are used for measurements processes. However, it is difficult to pinpoint which approach is suitable for a measurement process, as every approach has its own advantages and disadvantages. To address this issue, this study intends to represent a methodology that supports selecting the optimal optical measurement system by comparing multiple system configurations and performing physical measurements based on common types of surface metrology application requirements in the semiconductor industry. In this study, the selection process is outlined using process flow charts, and a comparative study is performed among three system configurations by physically measuring a silicon wafer, a BGA, and a substrate-bonded die on each system. descriptive statistics, Statistical Process Control (SPC) limits, and ANOVA were utilized to analyze the measurement data. In addition, a weighted decision matrix was created to help identify optimal system configurations. White Light Interferometry (WLI) technology performs best in terms of measurement precision, accuracy, and repeatability, but requires much longer measurement times. Even though the system utilizing chromatic confocal technology and a line sensor-type objective offered the fastest cycle time, it had the worst performance in terms of precision and accuracy. The insights of this study help in the different types of surface metrology practices in manufacturing facilities and research and development labs by determining the optimal measurement system configuration. [ABSTRACT FROM AUTHOR]
Copyright of Measurement (02632241) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 194168607
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Evaluating the selection process for optical sensor system configurations used in surface metrology applications.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Sokolov%2C+Alexandr+M%2E%22">Sokolov, Alexandr M.</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> asokolov@astate.edu</i><br /><searchLink fieldCode="AR" term="%22Simpson%2C+Travis%22">Simpson, Travis</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> travis.simpson@smail.astate.edu</i><br /><searchLink fieldCode="AR" term="%22Ahmed%2C+Ifaz%22">Ahmed, Ifaz</searchLink><relatesTo>1</relatesTo> (AUTHOR)<i> Ifaz.ahmed@smail.astate.edu</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Measurement+%2802632241%29%22">Measurement (02632241)</searchLink>. Jun2026, Vol. 280, pN.PAG-N.PAG. 1p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Interferometry%22">Interferometry</searchLink><br /><searchLink fieldCode="DE" term="%22Ball+grid+array+technology%22">Ball grid array technology</searchLink><br /><searchLink fieldCode="DE" term="%22Confocal+microscopy%22">Confocal microscopy</searchLink><br /><searchLink fieldCode="DE" term="%22Optical+sensors%22">Optical sensors</searchLink><br /><searchLink fieldCode="DE" term="%22Surface+roughness+measurement%22">Surface roughness measurement</searchLink><br /><searchLink fieldCode="DE" term="%22Substrates+%28Materials+science%29%22">Substrates (Materials science)</searchLink><br /><searchLink fieldCode="DE" term="%22Microfabrication%22">Microfabrication</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: • A comparative analysis of the performance of three surface metrology systems is conducted. • The attributes of the silicon wafer, the Ball Grid Array (BGA), and the substrate-bonded die are measured. • Different measurement systems are suitable for different cases. • White Light Interferometry performs best but requires higher measurement times. • A weighted decision matrix identifies optimal system configurations. Surface metrology is very crucial for precision manufacturing processes, especially in the semiconductor industry, to measure different characteristics of silicon wafers or a Ball Grid Array (BGA). Various surface metrology approaches are used for measurements processes. However, it is difficult to pinpoint which approach is suitable for a measurement process, as every approach has its own advantages and disadvantages. To address this issue, this study intends to represent a methodology that supports selecting the optimal optical measurement system by comparing multiple system configurations and performing physical measurements based on common types of surface metrology application requirements in the semiconductor industry. In this study, the selection process is outlined using process flow charts, and a comparative study is performed among three system configurations by physically measuring a silicon wafer, a BGA, and a substrate-bonded die on each system. descriptive statistics, Statistical Process Control (SPC) limits, and ANOVA were utilized to analyze the measurement data. In addition, a weighted decision matrix was created to help identify optimal system configurations. White Light Interferometry (WLI) technology performs best in terms of measurement precision, accuracy, and repeatability, but requires much longer measurement times. Even though the system utilizing chromatic confocal technology and a line sensor-type objective offered the fastest cycle time, it had the worst performance in terms of precision and accuracy. The insights of this study help in the different types of surface metrology practices in manufacturing facilities and research and development labs by determining the optimal measurement system configuration. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Measurement (02632241) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=194168607
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1016/j.measurement.2026.121928
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 1
        StartPage: N.PAG
    Subjects:
      – SubjectFull: Interferometry
        Type: general
      – SubjectFull: Ball grid array technology
        Type: general
      – SubjectFull: Confocal microscopy
        Type: general
      – SubjectFull: Optical sensors
        Type: general
      – SubjectFull: Surface roughness measurement
        Type: general
      – SubjectFull: Substrates (Materials science)
        Type: general
      – SubjectFull: Microfabrication
        Type: general
    Titles:
      – TitleFull: Evaluating the selection process for optical sensor system configurations used in surface metrology applications.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Sokolov, Alexandr M.
      – PersonEntity:
          Name:
            NameFull: Simpson, Travis
      – PersonEntity:
          Name:
            NameFull: Ahmed, Ifaz
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 30
              M: 06
              Text: Jun2026
              Type: published
              Y: 2026
          Identifiers:
            – Type: issn-print
              Value: 02632241
          Numbering:
            – Type: volume
              Value: 280
          Titles:
            – TitleFull: Measurement (02632241)
              Type: main
ResultId 1