Bibliographic Details
| Title: |
Real-time heart sound denoising for cardiac disease detection using SVM. |
| Authors: |
Vigian, Shatiswaran1, Ramasamy, R. Kanesaraj1 r.kanesaraj@mmu.edu.my, Abdullah, Junaidi1 |
| Source: |
Sound & Vibration. 2026, Vol. 60 Issue 3, p1-13. 13p. |
| Subjects: |
Signal denoising, Wavelet transforms, Sound recordings, Computer-aided diagnosis, Support vector machines, Signal-to-noise ratio, Cardiovascular disease diagnosis |
| Abstract: |
Heart-sound recordings are highly susceptible to environmental and physiological noise, which complicates clinical interpretation and reduces the reliability of automated diagnostic systems. Effective denoising is therefore essential for preserving waveform morphology and enabling accurate feature extraction. This study proposes a heart-sound-specific wavelet approach and evaluates its denoising performance in comparison with conventional wavelets and support vector machine (SVM)-based methods. The method was assessed using publicly available datasets, including PASCAL and PhysioNet, which provide diverse normal and pathological phonocardiogram (PCG) recordings. Uniform and Gaussian white noise were added at varying signal-to-noise ratios (SNRs) to simulate realistic acquisition environments. Denoising performance was quantified using cross-correlation coefficients, SNR improvement, root-mean-squared error (RMSE), and mean absolute error (MAE). Results demonstrate that the proposed heart-sound wavelet achieved superior noise-suppression capability and a 7% performance gain over commonly used Db and Bior wavelets, while maintaining waveform integrity. Subsequent classification experiments showed that denoising quality directly influenced diagnostic performance: the model achieved 0.87 accuracy, 0.81 precision, and 0.83 sensitivity on the PASCAL dataset, and 0.997 accuracy, 0.946 sensitivity, and 0.944 precision on PhysioNet. These findings highlight the potential of tailored wavelet-based denoising to enhance automated heart-sound analysis and support more robust clinical and embedded diagnostic applications. [ABSTRACT FROM AUTHOR] |
|
Copyright of Sound & Vibration is the property of Academic Publishing and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Database: |
Engineering Source |