Automated Microaneurysm Detection Using Local Contrast Normalization and Local Vessel Detection.

Saved in:
Bibliographic Details
Title: Automated Microaneurysm Detection Using Local Contrast Normalization and Local Vessel Detection.
Authors: Fleming, Alan D.1 a.fleming@biomed.abdn.ac.uk, Philip, Sam2, Goatman, Keith A.1, Olson, John A.2, Sharp, Peter F.1
Source: IEEE Transactions on Medical Imaging. Sep2006, Vol. 25 Issue 9, p1223-1232. 10p.
Subjects: Imaging systems, Eye diseases, Retina, Health, Photography, Automation
Abstract: Screening programs using retinal photography for the detection of diabetic eye disease are being introduced in the U.K. and elsewhere. Automatic grading of the images is being considered by health boards so that the human grading task is reduced. Microaneurysms (MAs) are the earliest sign of this disease and so are very important for classifying whether images show signs of retinopathy. This paper describes automatic methods for MA detection and shows how image contrast normalization can improve the ability to distinguish between MAs and other dots that occur on the retina. Various methods for contrast normalization are compared. Best results were obtained with a method that uses the watershed transform to derive a region that contains no vessels or other lesions. Dots within vessels are handled successfully using a local vessel detection technique. Results are presented for detection of individual MAs and for detection of images containing MAs. Images containing MAs are detected with sensitivity 85.4% and specificity 83.1%. [ABSTRACT FROM AUTHOR]
Copyright of IEEE Transactions on Medical Imaging is the property of IEEE and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Screening programs using retinal photography for the detection of diabetic eye disease are being introduced in the U.K. and elsewhere. Automatic grading of the images is being considered by health boards so that the human grading task is reduced. Microaneurysms (MAs) are the earliest sign of this disease and so are very important for classifying whether images show signs of retinopathy. This paper describes automatic methods for MA detection and shows how image contrast normalization can improve the ability to distinguish between MAs and other dots that occur on the retina. Various methods for contrast normalization are compared. Best results were obtained with a method that uses the watershed transform to derive a region that contains no vessels or other lesions. Dots within vessels are handled successfully using a local vessel detection technique. Results are presented for detection of individual MAs and for detection of images containing MAs. Images containing MAs are detected with sensitivity 85.4% and specificity 83.1%. [ABSTRACT FROM AUTHOR]
ISSN:02780062
DOI:10.1109/TMI.2006.879953