An arc-sequencing algorithm for intensity modulated arc therapy.

Saved in:
Bibliographic Details
Title: An arc-sequencing algorithm for intensity modulated arc therapy.
Authors: Shepard, D. M.1, Cao, D.1, Afghan, M. K. N.1, Earl, M. A.2
Source: Medical Physics. Feb2007, Vol. 34 Issue 2, p464-470. 7p.
Subjects: Algorithms, Simulated annealing, Radiotherapy, Electrotherapeutics, Medical radiology, Medical physics
Abstract: Intensity modulated arc therapy (IMAT) is an intensity modulated radiation therapy delivery technique originally proposed as an alternative to tomotherapy. IMAT uses a series of overlapping arcs to deliver optimized intensity patterns from each beam direction. The full potential of IMAT has gone largely unrealized due in part to a lack of robust and commercially available inverse planning tools. To address this, we have implemented an IMAT arc-sequencing algorithm that translates optimized intensity maps into deliverable IMAT plans. The sequencing algorithm uses simulated annealing to simultaneously optimize the aperture shapes and weights throughout each arc. The sequencer enforces the delivery constraints while minimizing the discrepancies between the optimized and sequenced intensity maps. The performance of the algorithm has been tested for ten patient cases (3 prostate, 3 brain, 2 head-and-neck, 1 lung, and 1 pancreas). Seven coplanar IMAT plans were created using an average of 4.6 arcs and 685 monitor units. Additionally, three noncoplanar plans were created using an average of 16 arcs and 498 monitor units. The results demonstrate that the arc sequencer can provide efficient and highly conformal IMAT plans. An average sequencing time of approximately 20 min was observed. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 23908983
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: An arc-sequencing algorithm for intensity modulated arc therapy.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Shepard%2C+D%2E+M%2E%22">Shepard, D. M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Cao%2C+D%2E%22">Cao, D.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Afghan%2C+M%2E+K%2E+N%2E%22">Afghan, M. K. N.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Earl%2C+M%2E+A%2E%22">Earl, M. A.</searchLink><relatesTo>2</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Feb2007, Vol. 34 Issue 2, p464-470. 7p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Algorithms%22">Algorithms</searchLink><br /><searchLink fieldCode="DE" term="%22Simulated+annealing%22">Simulated annealing</searchLink><br /><searchLink fieldCode="DE" term="%22Radiotherapy%22">Radiotherapy</searchLink><br /><searchLink fieldCode="DE" term="%22Electrotherapeutics%22">Electrotherapeutics</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+radiology%22">Medical radiology</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+physics%22">Medical physics</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Intensity modulated arc therapy (IMAT) is an intensity modulated radiation therapy delivery technique originally proposed as an alternative to tomotherapy. IMAT uses a series of overlapping arcs to deliver optimized intensity patterns from each beam direction. The full potential of IMAT has gone largely unrealized due in part to a lack of robust and commercially available inverse planning tools. To address this, we have implemented an IMAT arc-sequencing algorithm that translates optimized intensity maps into deliverable IMAT plans. The sequencing algorithm uses simulated annealing to simultaneously optimize the aperture shapes and weights throughout each arc. The sequencer enforces the delivery constraints while minimizing the discrepancies between the optimized and sequenced intensity maps. The performance of the algorithm has been tested for ten patient cases (3 prostate, 3 brain, 2 head-and-neck, 1 lung, and 1 pancreas). Seven coplanar IMAT plans were created using an average of 4.6 arcs and 685 monitor units. Additionally, three noncoplanar plans were created using an average of 16 arcs and 498 monitor units. The results demonstrate that the arc sequencer can provide efficient and highly conformal IMAT plans. An average sequencing time of approximately 20 min was observed. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=23908983
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1118/1.2409239
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 7
        StartPage: 464
    Subjects:
      – SubjectFull: Algorithms
        Type: general
      – SubjectFull: Simulated annealing
        Type: general
      – SubjectFull: Radiotherapy
        Type: general
      – SubjectFull: Electrotherapeutics
        Type: general
      – SubjectFull: Medical radiology
        Type: general
      – SubjectFull: Medical physics
        Type: general
    Titles:
      – TitleFull: An arc-sequencing algorithm for intensity modulated arc therapy.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Shepard, D. M.
      – PersonEntity:
          Name:
            NameFull: Cao, D.
      – PersonEntity:
          Name:
            NameFull: Afghan, M. K. N.
      – PersonEntity:
          Name:
            NameFull: Earl, M. A.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 02
              Text: Feb2007
              Type: published
              Y: 2007
          Identifiers:
            – Type: issn-print
              Value: 00942405
          Numbering:
            – Type: volume
              Value: 34
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: Medical Physics
              Type: main
ResultId 1