An arc-sequencing algorithm for intensity modulated arc therapy.
Saved in:
| Title: | An arc-sequencing algorithm for intensity modulated arc therapy. |
|---|---|
| Authors: | Shepard, D. M.1, Cao, D.1, Afghan, M. K. N.1, Earl, M. A.2 |
| Source: | Medical Physics. Feb2007, Vol. 34 Issue 2, p464-470. 7p. |
| Subjects: | Algorithms, Simulated annealing, Radiotherapy, Electrotherapeutics, Medical radiology, Medical physics |
| Abstract: | Intensity modulated arc therapy (IMAT) is an intensity modulated radiation therapy delivery technique originally proposed as an alternative to tomotherapy. IMAT uses a series of overlapping arcs to deliver optimized intensity patterns from each beam direction. The full potential of IMAT has gone largely unrealized due in part to a lack of robust and commercially available inverse planning tools. To address this, we have implemented an IMAT arc-sequencing algorithm that translates optimized intensity maps into deliverable IMAT plans. The sequencing algorithm uses simulated annealing to simultaneously optimize the aperture shapes and weights throughout each arc. The sequencer enforces the delivery constraints while minimizing the discrepancies between the optimized and sequenced intensity maps. The performance of the algorithm has been tested for ten patient cases (3 prostate, 3 brain, 2 head-and-neck, 1 lung, and 1 pancreas). Seven coplanar IMAT plans were created using an average of 4.6 arcs and 685 monitor units. Additionally, three noncoplanar plans were created using an average of 16 arcs and 498 monitor units. The results demonstrate that the arc sequencer can provide efficient and highly conformal IMAT plans. An average sequencing time of approximately 20 min was observed. [ABSTRACT FROM AUTHOR] |
| Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 23908983 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: An arc-sequencing algorithm for intensity modulated arc therapy. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Shepard%2C+D%2E+M%2E%22">Shepard, D. M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Cao%2C+D%2E%22">Cao, D.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Afghan%2C+M%2E+K%2E+N%2E%22">Afghan, M. K. N.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Earl%2C+M%2E+A%2E%22">Earl, M. A.</searchLink><relatesTo>2</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Medical+Physics%22">Medical Physics</searchLink>. Feb2007, Vol. 34 Issue 2, p464-470. 7p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Algorithms%22">Algorithms</searchLink><br /><searchLink fieldCode="DE" term="%22Simulated+annealing%22">Simulated annealing</searchLink><br /><searchLink fieldCode="DE" term="%22Radiotherapy%22">Radiotherapy</searchLink><br /><searchLink fieldCode="DE" term="%22Electrotherapeutics%22">Electrotherapeutics</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+radiology%22">Medical radiology</searchLink><br /><searchLink fieldCode="DE" term="%22Medical+physics%22">Medical physics</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Intensity modulated arc therapy (IMAT) is an intensity modulated radiation therapy delivery technique originally proposed as an alternative to tomotherapy. IMAT uses a series of overlapping arcs to deliver optimized intensity patterns from each beam direction. The full potential of IMAT has gone largely unrealized due in part to a lack of robust and commercially available inverse planning tools. To address this, we have implemented an IMAT arc-sequencing algorithm that translates optimized intensity maps into deliverable IMAT plans. The sequencing algorithm uses simulated annealing to simultaneously optimize the aperture shapes and weights throughout each arc. The sequencer enforces the delivery constraints while minimizing the discrepancies between the optimized and sequenced intensity maps. The performance of the algorithm has been tested for ten patient cases (3 prostate, 3 brain, 2 head-and-neck, 1 lung, and 1 pancreas). Seven coplanar IMAT plans were created using an average of 4.6 arcs and 685 monitor units. Additionally, three noncoplanar plans were created using an average of 16 arcs and 498 monitor units. The results demonstrate that the arc sequencer can provide efficient and highly conformal IMAT plans. An average sequencing time of approximately 20 min was observed. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=23908983 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1118/1.2409239 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 7 StartPage: 464 Subjects: – SubjectFull: Algorithms Type: general – SubjectFull: Simulated annealing Type: general – SubjectFull: Radiotherapy Type: general – SubjectFull: Electrotherapeutics Type: general – SubjectFull: Medical radiology Type: general – SubjectFull: Medical physics Type: general Titles: – TitleFull: An arc-sequencing algorithm for intensity modulated arc therapy. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Shepard, D. M. – PersonEntity: Name: NameFull: Cao, D. – PersonEntity: Name: NameFull: Afghan, M. K. N. – PersonEntity: Name: NameFull: Earl, M. A. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 02 Text: Feb2007 Type: published Y: 2007 Identifiers: – Type: issn-print Value: 00942405 Numbering: – Type: volume Value: 34 – Type: issue Value: 2 Titles: – TitleFull: Medical Physics Type: main |
| ResultId | 1 |