Thermal ablation of uterine fibroids using MR-guided focused ultrasound-a truly non-invasive treatment modality.
Saved in:
| Title: | Thermal ablation of uterine fibroids using MR-guided focused ultrasound-a truly non-invasive treatment modality. |
|---|---|
| Authors: | Chapman, Alexander1,2 alex.chapman@icr.ac.uk, Haar, Gail Ter1 gail.terhaar@icr.ac.uk, ter Haar, Gail (AUTHOR) |
| Source: | European Radiology. Oct2007, Vol. 17 Issue 10, p2505-2511. 7p. 2 Color Photographs, 2 Black and White Photographs. |
| Subjects: | Medical imaging systems, Smooth muscle tumors, Uterine surgery, Diagnostic imaging, Magnetic resonance imaging, Uterine fibroid treatment, Uterine fibroids, Uterine tumors, Ultrasonic therapy, Diagnosis, Tumor treatment |
| Abstract: | Uterine fibroids are a significant source of morbidity for women of reproductive age. Definitive treatment has traditionally been a hysterectomy, but increasingly women are not prepared to undergo such an invasive procedure for a benign and usually self-limiting condition. Although a number of minimally invasive techniques are now available, focused ultrasound has a considerable advantage over them as it is completely non-invasive and does not require an anaesthetic. Improvements in imaging techniques, particularly magnetic resonance imaging (MRI), have enabled the accurate planning, targeting and monitoring of treatments. We review the early experience of focused ultrasound surgery for the treatment of fibroids, and, in particular, the results of the recent phase I, II and III multi-centre clinical trials. These trials and other studies which demonstrate that MR-guided focused ultrasound ablation is feasible, safe and appears to have an efficacy that is comparable with other treatment modalities are described. This technique has the advantages of being non-invasive and being deliverable as an out-patient procedure. [ABSTRACT FROM AUTHOR] |
| Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |