Comparison of sensitivity and reading time for the use of computer-aided detection (CAD) of pulmonary nodules at MDCT as concurrent or second reader.
Saved in:
| Title: | Comparison of sensitivity and reading time for the use of computer-aided detection (CAD) of pulmonary nodules at MDCT as concurrent or second reader. |
|---|---|
| Authors: | Beyer, F.1 beyerf@uni-muenster.de, Zierott, L.1, Fallenberg, E.1,2, Juergens, K.1, Stoeckel, J.3, Heindel, W.1, Wormanns, D.1,4, Fallenberg, E M (AUTHOR), Juergens, K U (AUTHOR) |
| Source: | European Radiology. Nov2007, Vol. 17 Issue 11, p2941-2947. 7p. 1 Color Photograph, 1 Black and White Photograph, 1 Diagram, 4 Charts, 5 Graphs. |
| Subjects: | Lung diseases, Tomography, Radiologists, Medical radiography, Quantitative research, Artificial intelligence, Comparative studies, Computed tomography, Diagnostic errors, Diagnostic imaging, Longitudinal method, Lung tumors, Research methodology, Medical cooperation, Computers in medicine, Research, Research evaluation, Time, Task performance, Evaluation research, Research bias, Retrospective studies, Solitary pulmonary nodule, Equipment & supplies |
| Abstract: | The purpose of this study was to compare sensitivity for detection of pulmonary nodules in MDCT scans and reading time of radiologists when using CAD as the second reader (SR) respectively concurrent reader (CR). Four radiologists analyzed 50 chest MDCT scans chosen from clinical routine two times and marked all detected pulmonary nodules: first with CAD as CR (display of CAD results immediately in the reading session) and later (median 14 weeks) with CAD as SR (display of CAD markers after completion of first reading without CAD). A Siemens LungCAD prototype was used. Sensitivities for detection of nodules and reading times were recorded. Sensitivity of reading with CAD as SR was significantly higher than reading without CAD (p < 0.001) and CAD as CR (p < 0.001). For nodule size of 1.75 mm or above no significant sensitivity difference between CAD as CR and reading without CAD was observed; e.g., for nodules above 4 mm sensitivity was 68% without CAD, 68% with CAD as CR (p = 0.45) and 75% with CAD as SR (p < 0.001). Reading time was significantly shorter for CR (274 s) compared to reading without CAD (294 s; p = 0.04) and SR (337 s; p < 0.001). In our study CAD could either speed up reading of chest CT cases for pulmonary nodules without relevant loss of sensitivity when used as CR, or it increased sensitivity at the cost of longer reading times when used as SR. [ABSTRACT FROM AUTHOR] |
| Copyright of European Radiology is the property of Springer Nature and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |