Computer-aided evaluation of anatomical accuracy of image fusion between X-ray CT and SPECT

Saved in:
Bibliographic Details
Title: Computer-aided evaluation of anatomical accuracy of image fusion between X-ray CT and SPECT
Authors: Han, Jingfeng1 jingfeng@informatik.uni-erlangen.de, Köstler, Harald2, Bennewitz, Christian3, Kuwert, Torsten3, Hornegger, Joachim1
Source: Computerized Medical Imaging & Graphics. Jul2008, Vol. 32 Issue 5, p388-395. 8p.
Subjects: Tomography, Scanning systems, Image transmission, Medical imaging systems
Abstract: Abstract: Hybrid scanners, which enable the performance of single photon emission computed tomography (SPECT) and X-ray computed tomography (CT) in one imaging session, have considerable diagnostic potential. However, evaluating the anatomical accuracy of image fusion inherent to these systems remains a challenge. This paper proposes a method for evaluating this variable with minimum user interaction. It focuses on measuring the distance between the centers of gravity of the SPECT hot spot and its counterpart in the CT image. A localized maximally stable extremal regions method is proposed to automatically segment SPECT hot spots, while the corresponding CT structures are segmented by the semi-automatic random walk method, based on a fast multigrid solver. Accuracy and reproducibility of the validation method have been preliminary confirmed by the test with 21 clinical data-sets. [Copyright &y& Elsevier]
Copyright of Computerized Medical Imaging & Graphics is the property of Pergamon Press - An Imprint of Elsevier Science and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Abstract: Hybrid scanners, which enable the performance of single photon emission computed tomography (SPECT) and X-ray computed tomography (CT) in one imaging session, have considerable diagnostic potential. However, evaluating the anatomical accuracy of image fusion inherent to these systems remains a challenge. This paper proposes a method for evaluating this variable with minimum user interaction. It focuses on measuring the distance between the centers of gravity of the SPECT hot spot and its counterpart in the CT image. A localized maximally stable extremal regions method is proposed to automatically segment SPECT hot spots, while the corresponding CT structures are segmented by the semi-automatic random walk method, based on a fast multigrid solver. Accuracy and reproducibility of the validation method have been preliminary confirmed by the test with 21 clinical data-sets. [Copyright &y& Elsevier]
ISSN:08956111