A novel technique for the characterization of a HPGe detector response based on pulse shape comparison

Saved in:
Bibliographic Details
Title: A novel technique for the characterization of a HPGe detector response based on pulse shape comparison
Authors: Crespi, F.C.L.1, Camera, F. camera@mi.infn.it, Million, B.1, Sassi, M.1, Wieland, O.1, Bracco, A.1
Source: Nuclear Instruments & Methods in Physics Research Section A. Aug2008, Vol. 593 Issue 3, p440-447. 8p.
Subjects: Simulation methods & models, Signal detection, Detectors, Gamma rays
Abstract: Abstract: A novel technique for measuring the HPGe detector pulse shape as a function of the γ-ray interaction position inside the detector volume is presented. This technique is based on a specific pulse shape comparison procedure. Its main feature is that it allows to characterize the 3D position response of a HPGe segmented detector in a much shorter time as compared with the standard coincidence techniques. The method was first validated using a GEANT simulation of a 36-fold HPGe AGATA detector realized taking into account the effects of the electronic chain response and electrical noise on the calculated signal shape. This procedure was then applied to extract experimentally the position response of a non-segmented coaxial HPGe detector along the radial direction, using a 438MBq 137Cs collimated γ-source. The results of this measurement show a dependence of the pulse shape as a function of γ-ray interaction radial coordinate consistent with that obtained with calculations. The signal acquisition rate reached using this characterization technique allows to realize a full scan of a large volume highly segmented HPGe detector in less than a week. [Copyright &y& Elsevier]
Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Abstract: A novel technique for measuring the HPGe detector pulse shape as a function of the γ-ray interaction position inside the detector volume is presented. This technique is based on a specific pulse shape comparison procedure. Its main feature is that it allows to characterize the 3D position response of a HPGe segmented detector in a much shorter time as compared with the standard coincidence techniques. The method was first validated using a GEANT simulation of a 36-fold HPGe AGATA detector realized taking into account the effects of the electronic chain response and electrical noise on the calculated signal shape. This procedure was then applied to extract experimentally the position response of a non-segmented coaxial HPGe detector along the radial direction, using a 438MBq 137Cs collimated γ-source. The results of this measurement show a dependence of the pulse shape as a function of γ-ray interaction radial coordinate consistent with that obtained with calculations. The signal acquisition rate reached using this characterization technique allows to realize a full scan of a large volume highly segmented HPGe detector in less than a week. [Copyright &y& Elsevier]
ISSN:01689002
DOI:10.1016/j.nima.2008.05.057