Column-joint assembly in RC columns strengthened by steel caging.

Saved in:
Bibliographic Details
Title: Column-joint assembly in RC columns strengthened by steel caging.
Authors: Adam, Jose M.1, Ivorra, Salvador2, Pallares, Francisco J.3, Giménez, Ester4, Calderón, Pedro A.5
Source: Proceedings of the Institution of Civil Engineers: Structures & Buildings. Dec2008, Vol. 161 Issue 6, p337-348. 12p.
Subjects: Concrete columns, Iron & steel columns, Construction materials, Strength of materials, Load factor design, Finite element method
Abstract: The strengthening of reinforced concrete columns by steel cages is one of various techniques available to increase ultimate column loads. Different researchers have shown the importance of the beam--column joint on the behaviour of columns strengthened by steel cages. This paper presents a parametric study using finite element models carried out with the aim of analysing the influence of the beam--column joint on the behaviour of axially loaded reinforced concrete columns strengthened by this technique. A design rule is proposed to provide a means of estimating the ultimate load capacity of column--joint assembly and recommendations are given concerning the design of the steel cage. [ABSTRACT FROM AUTHOR]
Copyright of Proceedings of the Institution of Civil Engineers: Structures & Buildings is the property of Thomas Telford Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:The strengthening of reinforced concrete columns by steel cages is one of various techniques available to increase ultimate column loads. Different researchers have shown the importance of the beam--column joint on the behaviour of columns strengthened by steel cages. This paper presents a parametric study using finite element models carried out with the aim of analysing the influence of the beam--column joint on the behaviour of axially loaded reinforced concrete columns strengthened by this technique. A design rule is proposed to provide a means of estimating the ultimate load capacity of column--joint assembly and recommendations are given concerning the design of the steel cage. [ABSTRACT FROM AUTHOR]
ISSN:09650911