Transferred charge of brush discharges in explosive gas atmospheres – A verification of the ignition threshold limits

Saved in:
Bibliographic Details
Title: Transferred charge of brush discharges in explosive gas atmospheres – A verification of the ignition threshold limits
Authors: Langer, T. tim.langer@ptb.de, Möckel, D.1, Beyer, M.1
Source: Journal of Electrostatics. Jun2011, Vol. 69 Issue 3, p200-205. 6p.
Subjects: Atmosphere, Charge transfer, Hydrogen, Alkenes, Propane, Mixtures, Electrostatics
Abstract: Abstract: A wide series of experiments has been performed to check the incentivity of hydrogen/air, ethene/air and propane/air mixtures due to brush discharges. Thereby, the transferred charge as a criterion to judge the ignition potential is determined to verify the thresholds of transferred charge given in the standards IEC 60079-0 and in EN 13463-1. These thresholds have never been examined directly in an experiment before. It is stated that the thresholds for explosion group IIA, IIB and IIC represent different levels of safety. Using adequate thresholds the criterion of transferred charge is suitable for a judgement of potential electrostatic ignition sources. [Copyright &y& Elsevier]
Copyright of Journal of Electrostatics is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Abstract: A wide series of experiments has been performed to check the incentivity of hydrogen/air, ethene/air and propane/air mixtures due to brush discharges. Thereby, the transferred charge as a criterion to judge the ignition potential is determined to verify the thresholds of transferred charge given in the standards IEC 60079-0 and in EN 13463-1. These thresholds have never been examined directly in an experiment before. It is stated that the thresholds for explosion group IIA, IIB and IIC represent different levels of safety. Using adequate thresholds the criterion of transferred charge is suitable for a judgement of potential electrostatic ignition sources. [Copyright &y& Elsevier]
ISSN:03043886
DOI:10.1016/j.elstat.2011.03.010