Transferred charge of brush discharges in explosive gas atmospheres – A verification of the ignition threshold limits
Saved in:
| Title: | Transferred charge of brush discharges in explosive gas atmospheres – A verification of the ignition threshold limits |
|---|---|
| Authors: | Langer, T. tim.langer@ptb.de, Möckel, D.1, Beyer, M.1 |
| Source: | Journal of Electrostatics. Jun2011, Vol. 69 Issue 3, p200-205. 6p. |
| Subjects: | Atmosphere, Charge transfer, Hydrogen, Alkenes, Propane, Mixtures, Electrostatics |
| Abstract: | Abstract: A wide series of experiments has been performed to check the incentivity of hydrogen/air, ethene/air and propane/air mixtures due to brush discharges. Thereby, the transferred charge as a criterion to judge the ignition potential is determined to verify the thresholds of transferred charge given in the standards IEC 60079-0 and in EN 13463-1. These thresholds have never been examined directly in an experiment before. It is stated that the thresholds for explosion group IIA, IIB and IIC represent different levels of safety. Using adequate thresholds the criterion of transferred charge is suitable for a judgement of potential electrostatic ignition sources. [Copyright &y& Elsevier] |
| Copyright of Journal of Electrostatics is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 60927348 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Transferred charge of brush discharges in explosive gas atmospheres – A verification of the ignition threshold limits – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Langer%2C+T%2E%22">Langer, T.</searchLink><i> tim.langer@ptb.de</i><br /><searchLink fieldCode="AR" term="%22Möckel%2C+D%2E%22">Möckel, D.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Beyer%2C+M%2E%22">Beyer, M.</searchLink><relatesTo>1</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Journal+of+Electrostatics%22">Journal of Electrostatics</searchLink>. Jun2011, Vol. 69 Issue 3, p200-205. 6p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Atmosphere%22">Atmosphere</searchLink><br /><searchLink fieldCode="DE" term="%22Charge+transfer%22">Charge transfer</searchLink><br /><searchLink fieldCode="DE" term="%22Hydrogen%22">Hydrogen</searchLink><br /><searchLink fieldCode="DE" term="%22Alkenes%22">Alkenes</searchLink><br /><searchLink fieldCode="DE" term="%22Propane%22">Propane</searchLink><br /><searchLink fieldCode="DE" term="%22Mixtures%22">Mixtures</searchLink><br /><searchLink fieldCode="DE" term="%22Electrostatics%22">Electrostatics</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Abstract: A wide series of experiments has been performed to check the incentivity of hydrogen/air, ethene/air and propane/air mixtures due to brush discharges. Thereby, the transferred charge as a criterion to judge the ignition potential is determined to verify the thresholds of transferred charge given in the standards IEC 60079-0 and in EN 13463-1. These thresholds have never been examined directly in an experiment before. It is stated that the thresholds for explosion group IIA, IIB and IIC represent different levels of safety. Using adequate thresholds the criterion of transferred charge is suitable for a judgement of potential electrostatic ignition sources. [Copyright &y& Elsevier] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Journal of Electrostatics is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=60927348 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.elstat.2011.03.010 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 6 StartPage: 200 Subjects: – SubjectFull: Atmosphere Type: general – SubjectFull: Charge transfer Type: general – SubjectFull: Hydrogen Type: general – SubjectFull: Alkenes Type: general – SubjectFull: Propane Type: general – SubjectFull: Mixtures Type: general – SubjectFull: Electrostatics Type: general Titles: – TitleFull: Transferred charge of brush discharges in explosive gas atmospheres – A verification of the ignition threshold limits Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Langer, T. – PersonEntity: Name: NameFull: Möckel, D. – PersonEntity: Name: NameFull: Beyer, M. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 06 Text: Jun2011 Type: published Y: 2011 Identifiers: – Type: issn-print Value: 03043886 Numbering: – Type: volume Value: 69 – Type: issue Value: 3 Titles: – TitleFull: Journal of Electrostatics Type: main |
| ResultId | 1 |