A Compact Remote Monitoring System for a Three-Phase 10-kVA Energy-Efficient Switchable Distribution Transformer.

Saved in:
Bibliographic Details
Title: A Compact Remote Monitoring System for a Three-Phase 10-kVA Energy-Efficient Switchable Distribution Transformer.
Authors: Dharmawan, Hari Arief1, Ali, Sam A. M.2
Source: IEEE Transactions on Instrumentation & Measurement. Mar2012, Vol. 61 Issue 3, p618-628. 11p.
Subjects: Electric transformers testing, Electric machinery monitoring equipment, Ethernet, Electric power distribution equipment -- Maintenance & repair, Remote control
Abstract: Remote monitoring has been implemented in many areas. This paper introduces its specific application to a three-phase 10-kVA energy-efficient switchable distribution transformer. A designed embedded system and embedded Ethernet have been implemented to achieve a compact remote condition monitoring for the transformer. The embedded system performs acquisition of voltages, currents, and temperatures, controls the switching devices that connect the tappings of the transformer, and processes acquired data. Client and server applications were developed through the use of embedded Ethernet to enable remote monitoring through a local area network (LAN). Some protocols were developed as parts of software development of the whole system. Experimentation was done by applying the remote monitoring system to the transformer connected to three-phase variable supply voltage and load. Results of the experimentation by using a LAN available in the school revealed that the system can handle remote monitoring and control tasks for the transformer. [ABSTRACT FROM PUBLISHER]
Copyright of IEEE Transactions on Instrumentation & Measurement is the property of IEEE and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Remote monitoring has been implemented in many areas. This paper introduces its specific application to a three-phase 10-kVA energy-efficient switchable distribution transformer. A designed embedded system and embedded Ethernet have been implemented to achieve a compact remote condition monitoring for the transformer. The embedded system performs acquisition of voltages, currents, and temperatures, controls the switching devices that connect the tappings of the transformer, and processes acquired data. Client and server applications were developed through the use of embedded Ethernet to enable remote monitoring through a local area network (LAN). Some protocols were developed as parts of software development of the whole system. Experimentation was done by applying the remote monitoring system to the transformer connected to three-phase variable supply voltage and load. Results of the experimentation by using a LAN available in the school revealed that the system can handle remote monitoring and control tasks for the transformer. [ABSTRACT FROM PUBLISHER]
ISSN:00189456
DOI:10.1109/TIM.2011.2170497