Bibliographic Details
| Title: |
A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space |
| Authors: |
Liang, Tianshui1,2 liangtsh@mail.ustc.edu.cn, Lo, Siuming2, Wang, Xishi1, Liao, Guangxuan1 |
| Source: |
Procedia Engineering. Jun2012, Vol. 31, p734-738. 5p. |
| Subjects: |
Numerical analysis, Fire extinguishing agents, Large eddy simulation models, Turbulence, Flame, Spray combustion, Qualitative research |
| Abstract: |
Abstract: Spray fire is a primary disaster in machinery space. Previous studies demonstrated that small spray fires were difficult to extinguish with water mist. A numerical and experimental study of the process of water mist interacting with the small size spray fire was conducted. Studies on suppression of vertical spray fire and horizontal spray fire were carried out, respectively. Three-dimensional physical model was developed based on the experiments. The adopted numerical model is FLUENT. The Large eddy simulation (LES) method, laminar finite-rate model, and Discrete Phase Model were selected to solve the turbulent flame, turbulence-chemistry interaction and particles, respectively. There are qualitative agreements of simulation with the experiment. It was confirmed that water mist can suppress spray fires rapidly, and that the extinguishing time for vertical spray fires were relatively shorter. [Copyright &y& Elsevier] |
|
Copyright of Procedia Engineering is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Database: |
Engineering Source |