Bibliographic Details
| Title: |
Intrinsic ligament and triangular fibrocartilage complex (TFCC) tears of the wrist: comparison of isovolumetric 3D-THRIVE sequence MR arthrography and conventional MR image at 3 T |
| Authors: |
Lee, Young Han1, Choi, Yun Rak2, Kim, Sungjun1, Song, Ho-Taek1, Suh, Jin-Suck1 jss@yuhs.ac |
| Source: |
Magnetic Resonance Imaging (0730725X). Feb2013, Vol. 31 Issue 2, p221-226. 6p. |
| Subjects: |
Isochoric processes, Mathematical sequences, Tears (Body fluid), Protons, Medical imaging systems, Comparative studies |
| Abstract: |
Abstract: Purpose: The purpose of the study was to validate the diagnostic performance of high-resolution isovolumetric magnetic resonance arthrography (MRA) for intrinsic ligament and triangular fibrocartilage complex (TFCC) tears of the wrist as compared to conventional MR imaging (MRI). Materials and methods: Forty-eight patients with traumatic TFCC tears at arthroscopy were enrolled. All patients had underwent proton-density- and T2-weighted MRI before arthrography and three-dimensional T1 high-resolution isovolumetric examination (3D-THRIVE) MRA on a 3-T MR. We assessed the presence of scapholunate interosseous ligament (SLIL)/lunotriquetral interosseous ligament (LTIL) or TFCC tears using the arthroscopy as a gold standard. Results: Arthroscopy revealed 37 TFCC central tears, 15 TFCC peripheral tears, 20 SLIL tears and 13 LTIL tears. Sensitivities of MRI and MRA were 70.3% and 94.6% for detection of TFCC central tears, 60.0% and 93.3% for detection of TFCC peripheral tears, 65.0% and 85.0% for SLIL tears, and 61.5% and 84.6% for LTIL tears. The specificity of the MRI was 100% for the detection of ligaments and TFCC tears. The specificities of the MRA for detection of TFCC central tears, TFCC peripheral tears, SLIL tears and LTIL tears were 100%, 97%, 96.4% and 100%, respectively. Conclusion: Isovolumetric 3D-THRIVE wrist MRA provided better results for depiction of intrinsic ligament and TFCC tears than wrist MRI. [Copyright &y& Elsevier] |
|
Copyright of Magnetic Resonance Imaging (0730725X) is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Database: |
Engineering Source |