Alignment and retardance errors, and compensation of a channeled spectropolarimeter

Saved in:
Bibliographic Details
Title: Alignment and retardance errors, and compensation of a channeled spectropolarimeter
Authors: Mu, Tingkui tkmu@mail.xjtu.edu.cn, Zhang, Chunmin zcm@mail.xjtu.edu.cn, Jia, Chenling1, Ren, Wenyi1, Zhang, Lin1, Li, Qiwei1
Source: Optics Communications. May2013, Vol. 294, p88-95. 8p.
Subjects: Spectropolarimeters, Shear waves, Numerical analysis, Parameters (Statistics), Optical polarization, Error analysis in mathematics
Abstract: Abstract: A channeled spectropolarimeter''s alignment and retardance errors are theoretically analyzed. The channels of Stokes parameters are mixed by the alignment and retardance errors, and a mathematical basis for selecting optimal channels to reconstruct full Stokes parameters is provided. The reconstructed Stokes spectra would be distorted by the alignment errors. Quantifying the alignment errors as well as eliminating the retardance terms can be achieved by using two polarized reference beams sequentially. A general compensation procedure is proposed to account for the alignment errors, which also considers the potential misalignment in the two polarized reference beams. An analytical treatment is given, followed by a numerical example to demonstrate the effectiveness of this method. [Copyright &y& Elsevier]
Copyright of Optics Communications is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Abstract: A channeled spectropolarimeter''s alignment and retardance errors are theoretically analyzed. The channels of Stokes parameters are mixed by the alignment and retardance errors, and a mathematical basis for selecting optimal channels to reconstruct full Stokes parameters is provided. The reconstructed Stokes spectra would be distorted by the alignment errors. Quantifying the alignment errors as well as eliminating the retardance terms can be achieved by using two polarized reference beams sequentially. A general compensation procedure is proposed to account for the alignment errors, which also considers the potential misalignment in the two polarized reference beams. An analytical treatment is given, followed by a numerical example to demonstrate the effectiveness of this method. [Copyright &y& Elsevier]
ISSN:00304018
DOI:10.1016/j.optcom.2012.12.017