The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays.

Saved in:
Bibliographic Details
Title: The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays.
Authors: Rapp, B.1 benjamin.rapp@cea.fr, Perichon, N.1, Denoziere, M.1, Daures, J.1, Ostrowsky, A.1, Bordy, J.-M.1
Source: Physics in Medicine & Biology. 2013, Vol. 58 Issue 9, p2769-2786. 18p.
Subjects: Calorimeters, Metrology, Radiation dosimetry, Ionizing radiation, X-rays
Abstract: Water calorimeters are used to establish absorbed dose standards in several national metrology laboratories involved in ionizing radiation dosimetry. These calorimeters have been first used in high-energy photons of 60Co or accelerator beams, where the depth of measurement in water is large (5 or 10 cm). The LNE-LNHB laboratory has developed a specific calorimeter which makes measurements at low depth in water (down to 0.5 cm) easier, in order to fulfil the reference conditions required by the international dosimetry protocols for medium-energy x-rays. This new calorimeter was first used to measure the absorbed dose rate in water at a depth of 2 cm for six medium-energy x-ray reference beams with a tube potential from 80 to 300 kV. The relative combined standard uncertainty obtained on the absorbed dose rate to water is lower than 0.8%. An overview of the design of the calorimeter is given, followed by a detailed description of the calculation of the correction factors and the calorimetric measurements. [ABSTRACT FROM AUTHOR]
© 2025 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved (Copyright applies to all Abstracts.)
Database: Engineering Source
FullText Text:
  Availability: 0
Header DbId: egs
DbLabel: Engineering Source
An: 90049792
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Rapp%2C+B%2E%22">Rapp, B.</searchLink><relatesTo>1</relatesTo><i> benjamin.rapp@cea.fr</i><br /><searchLink fieldCode="AR" term="%22Perichon%2C+N%2E%22">Perichon, N.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Denoziere%2C+M%2E%22">Denoziere, M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Daures%2C+J%2E%22">Daures, J.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Ostrowsky%2C+A%2E%22">Ostrowsky, A.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Bordy%2C+J%2E-M%2E%22">Bordy, J.-M.</searchLink><relatesTo>1</relatesTo>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22Physics+in+Medicine+%26+Biology%22">Physics in Medicine & Biology</searchLink>. 2013, Vol. 58 Issue 9, p2769-2786. 18p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: <searchLink fieldCode="DE" term="%22Calorimeters%22">Calorimeters</searchLink><br /><searchLink fieldCode="DE" term="%22Metrology%22">Metrology</searchLink><br /><searchLink fieldCode="DE" term="%22Radiation+dosimetry%22">Radiation dosimetry</searchLink><br /><searchLink fieldCode="DE" term="%22Ionizing+radiation%22">Ionizing radiation</searchLink><br /><searchLink fieldCode="DE" term="%22X-rays%22">X-rays</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Water calorimeters are used to establish absorbed dose standards in several national metrology laboratories involved in ionizing radiation dosimetry. These calorimeters have been first used in high-energy photons of 60Co or accelerator beams, where the depth of measurement in water is large (5 or 10 cm). The LNE-LNHB laboratory has developed a specific calorimeter which makes measurements at low depth in water (down to 0.5 cm) easier, in order to fulfil the reference conditions required by the international dosimetry protocols for medium-energy x-rays. This new calorimeter was first used to measure the absorbed dose rate in water at a depth of 2 cm for six medium-energy x-ray reference beams with a tube potential from 80 to 300 kV. The relative combined standard uncertainty obtained on the absorbed dose rate to water is lower than 0.8%. An overview of the design of the calorimeter is given, followed by a detailed description of the calculation of the correction factors and the calorimetric measurements. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>© 2025 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=90049792
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1088/0031-9155/58/9/2769
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 18
        StartPage: 2769
    Subjects:
      – SubjectFull: Calorimeters
        Type: general
      – SubjectFull: Metrology
        Type: general
      – SubjectFull: Radiation dosimetry
        Type: general
      – SubjectFull: Ionizing radiation
        Type: general
      – SubjectFull: X-rays
        Type: general
    Titles:
      – TitleFull: The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Rapp, B.
      – PersonEntity:
          Name:
            NameFull: Perichon, N.
      – PersonEntity:
          Name:
            NameFull: Denoziere, M.
      – PersonEntity:
          Name:
            NameFull: Daures, J.
      – PersonEntity:
          Name:
            NameFull: Ostrowsky, A.
      – PersonEntity:
          Name:
            NameFull: Bordy, J.-M.
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 07
              M: 05
              Text: 2013
              Type: published
              Y: 2013
          Identifiers:
            – Type: issn-print
              Value: 00319155
          Numbering:
            – Type: volume
              Value: 58
            – Type: issue
              Value: 9
          Titles:
            – TitleFull: Physics in Medicine & Biology
              Type: main
ResultId 1