The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays.
Saved in:
| Title: | The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays. |
|---|---|
| Authors: | Rapp, B.1 benjamin.rapp@cea.fr, Perichon, N.1, Denoziere, M.1, Daures, J.1, Ostrowsky, A.1, Bordy, J.-M.1 |
| Source: | Physics in Medicine & Biology. 2013, Vol. 58 Issue 9, p2769-2786. 18p. |
| Subjects: | Calorimeters, Metrology, Radiation dosimetry, Ionizing radiation, X-rays |
| Abstract: | Water calorimeters are used to establish absorbed dose standards in several national metrology laboratories involved in ionizing radiation dosimetry. These calorimeters have been first used in high-energy photons of 60Co or accelerator beams, where the depth of measurement in water is large (5 or 10 cm). The LNE-LNHB laboratory has developed a specific calorimeter which makes measurements at low depth in water (down to 0.5 cm) easier, in order to fulfil the reference conditions required by the international dosimetry protocols for medium-energy x-rays. This new calorimeter was first used to measure the absorbed dose rate in water at a depth of 2 cm for six medium-energy x-ray reference beams with a tube potential from 80 to 300 kV. The relative combined standard uncertainty obtained on the absorbed dose rate to water is lower than 0.8%. An overview of the design of the calorimeter is given, followed by a detailed description of the calculation of the correction factors and the calorimetric measurements. [ABSTRACT FROM AUTHOR] |
| © 2025 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved (Copyright applies to all Abstracts.) | |
| Database: | Engineering Source |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: egs DbLabel: Engineering Source An: 90049792 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Rapp%2C+B%2E%22">Rapp, B.</searchLink><relatesTo>1</relatesTo><i> benjamin.rapp@cea.fr</i><br /><searchLink fieldCode="AR" term="%22Perichon%2C+N%2E%22">Perichon, N.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Denoziere%2C+M%2E%22">Denoziere, M.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Daures%2C+J%2E%22">Daures, J.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Ostrowsky%2C+A%2E%22">Ostrowsky, A.</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Bordy%2C+J%2E-M%2E%22">Bordy, J.-M.</searchLink><relatesTo>1</relatesTo> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Physics+in+Medicine+%26+Biology%22">Physics in Medicine & Biology</searchLink>. 2013, Vol. 58 Issue 9, p2769-2786. 18p. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22Calorimeters%22">Calorimeters</searchLink><br /><searchLink fieldCode="DE" term="%22Metrology%22">Metrology</searchLink><br /><searchLink fieldCode="DE" term="%22Radiation+dosimetry%22">Radiation dosimetry</searchLink><br /><searchLink fieldCode="DE" term="%22Ionizing+radiation%22">Ionizing radiation</searchLink><br /><searchLink fieldCode="DE" term="%22X-rays%22">X-rays</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Water calorimeters are used to establish absorbed dose standards in several national metrology laboratories involved in ionizing radiation dosimetry. These calorimeters have been first used in high-energy photons of 60Co or accelerator beams, where the depth of measurement in water is large (5 or 10 cm). The LNE-LNHB laboratory has developed a specific calorimeter which makes measurements at low depth in water (down to 0.5 cm) easier, in order to fulfil the reference conditions required by the international dosimetry protocols for medium-energy x-rays. This new calorimeter was first used to measure the absorbed dose rate in water at a depth of 2 cm for six medium-energy x-ray reference beams with a tube potential from 80 to 300 kV. The relative combined standard uncertainty obtained on the absorbed dose rate to water is lower than 0.8%. An overview of the design of the calorimeter is given, followed by a detailed description of the calculation of the correction factors and the calorimetric measurements. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>© 2025 IOP Publishing Ltd. All rights, including for text and data mining, AI training, and similar technologies, are reserved</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=egs&AN=90049792 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1088/0031-9155/58/9/2769 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 18 StartPage: 2769 Subjects: – SubjectFull: Calorimeters Type: general – SubjectFull: Metrology Type: general – SubjectFull: Radiation dosimetry Type: general – SubjectFull: Ionizing radiation Type: general – SubjectFull: X-rays Type: general Titles: – TitleFull: The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Rapp, B. – PersonEntity: Name: NameFull: Perichon, N. – PersonEntity: Name: NameFull: Denoziere, M. – PersonEntity: Name: NameFull: Daures, J. – PersonEntity: Name: NameFull: Ostrowsky, A. – PersonEntity: Name: NameFull: Bordy, J.-M. IsPartOfRelationships: – BibEntity: Dates: – D: 07 M: 05 Text: 2013 Type: published Y: 2013 Identifiers: – Type: issn-print Value: 00319155 Numbering: – Type: volume Value: 58 – Type: issue Value: 9 Titles: – TitleFull: Physics in Medicine & Biology Type: main |
| ResultId | 1 |