Examination of Mechanisms for Liquid-Air-Interface Corrosion of Steel in High Level Radioactive Waste Simulants.

Saved in:
Bibliographic Details
Title: Examination of Mechanisms for Liquid-Air-Interface Corrosion of Steel in High Level Radioactive Waste Simulants.
Authors: Xiaoji Li1, Gui, F.2, Hongbo Cong2, Brossia, C. S.2, Frankel, G. S.1 frankel.10@osu.edu
Source: Journal of The Electrochemical Society. 2013, Vol. 160 Issue 11, pC521-C530. 10p.
Subjects: Corrosion & anti-corrosives, Radioactive waste disposal, Meniscus (Anatomy), Silver nitrate, Electrodes
Abstract: Several hypothesized mechanisms of liquid-air-interface (LAI) corrosion in simplified simulants of high level liquid nuclear waste were investigated. The salt concentration cell theory is based on the possible development of an enhanced nitrate concentration or a depleted nitrite concentration in the meniscus solution compared to the bulk solution. In situ Raman spectroscopy was employed to monitor the time-dependent changes in nitrate concentration, nitrite concentration, and the nitrate-to-nitrite concentration ratio in the meniscus region during LAI corrosion. However, there was no evidence to support the proposed nitrate- or nitrite- salt concentration cell theory. The IR drop theory was ruled out as being the cause of LAI corrosion based on local potential measurements using customized micro-reference electrodes. A theory of CO2-induced local hydroxide depletion was tested with a small pH electrode. However, the meniscus and bulk solutions exhibited no difference in pH before the initiation of LAI corrosion under anodic potentiostatic polarization. A local acidification mechanism, which results from borderline passive dissolution of steel in the meniscus and subsequent hydrolysis similar to the phenomenon of crevice corrosion, remains possible. [ABSTRACT FROM AUTHOR]
Copyright of Journal of The Electrochemical Society is the property of IOP Publishing and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:Several hypothesized mechanisms of liquid-air-interface (LAI) corrosion in simplified simulants of high level liquid nuclear waste were investigated. The salt concentration cell theory is based on the possible development of an enhanced nitrate concentration or a depleted nitrite concentration in the meniscus solution compared to the bulk solution. In situ Raman spectroscopy was employed to monitor the time-dependent changes in nitrate concentration, nitrite concentration, and the nitrate-to-nitrite concentration ratio in the meniscus region during LAI corrosion. However, there was no evidence to support the proposed nitrate- or nitrite- salt concentration cell theory. The IR drop theory was ruled out as being the cause of LAI corrosion based on local potential measurements using customized micro-reference electrodes. A theory of CO2-induced local hydroxide depletion was tested with a small pH electrode. However, the meniscus and bulk solutions exhibited no difference in pH before the initiation of LAI corrosion under anodic potentiostatic polarization. A local acidification mechanism, which results from borderline passive dissolution of steel in the meniscus and subsequent hydrolysis similar to the phenomenon of crevice corrosion, remains possible. [ABSTRACT FROM AUTHOR]
ISSN:00134651