Test in a beam of large-area Micromegas chambers for sampling calorimetry.

Saved in:
Bibliographic Details
Title: Test in a beam of large-area Micromegas chambers for sampling calorimetry.
Authors: Adloff, C.1, Chefdeville, M.1 chefdevi@lapp.in2p3.fr, Dalmaz, A.1, Drancourt, C.1, Gaglione, R.1, Geffroy, N.1, Jacquemier, J.1, Karyotakis, Y.1, Koletsou, I.1, Peltier, F.1, Samarati, J.1, Vouters, G.1
Source: Nuclear Instruments & Methods in Physics Research Section A. Nov2014, Vol. 763, p221-231. 11p.
Subjects: Calorimetry, Linear systems, Prototypes, Stability (Mechanics), Performance evaluation
Abstract: The application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density deposits are prerequisites for achieving good energy resolution. A Micromegas-based hadronic calorimeter was proposed for an application at a future linear collider experiment and three technologically advanced prototypes of 1×1 m 2 were constructed. Their merits relative to the above-mentioned criteria are discussed on the basis of measurements performed at the CERN SPS test-beam facility. [ABSTRACT FROM AUTHOR]
Copyright of Nuclear Instruments & Methods in Physics Research Section A is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Engineering Source
Description
Abstract:The application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density deposits are prerequisites for achieving good energy resolution. A Micromegas-based hadronic calorimeter was proposed for an application at a future linear collider experiment and three technologically advanced prototypes of 1×1 m 2 were constructed. Their merits relative to the above-mentioned criteria are discussed on the basis of measurements performed at the CERN SPS test-beam facility. [ABSTRACT FROM AUTHOR]
ISSN:01689002