Multifrequency Narrowband Chirp Evoked Cervical Vestibular Myogenic Potentials: Evaluation of Responses in Normal-Hearing Young Adults.

Saved in:
Bibliographic Details
Title: Multifrequency Narrowband Chirp Evoked Cervical Vestibular Myogenic Potentials: Evaluation of Responses in Normal-Hearing Young Adults.
Authors: Lodha, Vidhi, Neupane, Anuj Kumar anujkneupane@gmail.com
Source: American Journal of Audiology. Dec2022, Vol. 31, p1191-1201. 11p. 2 Charts, 2 Graphs.
Subject Terms: *Hearing, *Data analysis, Evoked potentials (Electrophysiology), Statistics, Muscle contraction, Statistical reliability, Research evaluation, Intraclass correlation, Descriptive statistics, Acoustic stimulation, Neck muscles, Sternocleidomastoid muscle, Electromyography, Data analysis software, Friedman test (Statistics)
Abstract: Purpose: The study aimed to explore the various parameters of multifrequency narrowband Claus Elberling chirp (NB CE-chirp) evoked cervical vestibular evoked myogenic potentials (cVEMPs) in normal-hearing healthy young adults. The study also attempted to define the optimal frequency tuning characteristic of NB CE-chirp evoked cVEMPs. Method: cVEMP was performed on 26 young healthy adults using four different NB CE-chirps centered at 500, 1000, 2000, and 4000 Hz. The neck torsion method was applied for electrode placement. To have the acute recording, visual feedback of sternocleidomastoid muscle contraction was provided, and electromyography (EMG) scaling was done. Results: cVEMPs were present for 100% across all frequencies except at 4000 Hz. Amplitudes between each pair of frequencies were significantly different for EMG scaled and unscaled conditions. Frequency tuning was observed at 500 Hz regardless of scaling done. Positive peak 1 of cVEMP (P1) latencies showed no differences between frequencies while both negative peak 1 of cVEMP and the complex of positive peak 1 and negative peak 1 of cVEMP (P1N1) interpeak latency values decreased with increasing frequency. Interaural amplitude asymmetry ratio showed no difference between scaled and unscaled amplitudes. Intraclass correlation revealed a range of test--retest reliability across frequencies. EMG unscaled amplitude were having relatively lower test--retest reliability consistently across frequencies Conclusions: Differences in amplitudes between frequencies with a maximum at 500 Hz can be attributed to the low frequency centered saccular response. No differences in P1 were observed. Yet, N1 latency and P1N1 interpeak latency difference gradually shortened with the decrement in the stimulus duration as the stimulation frequency increased. The lower reliability of EMG unscaled amplitude across frequencies supports the need to use EMG scaling to avoid confounding variables related to muscle contraction. [ABSTRACT FROM AUTHOR]
Copyright of American Journal of Audiology is the property of American Speech-Language-Hearing Association and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Education Research Complete
FullText Links:
  – Type: pdflink
Text:
  Availability: 0
Header DbId: ehh
DbLabel: Education Research Complete
An: 160628913
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Multifrequency Narrowband Chirp Evoked Cervical Vestibular Myogenic Potentials: Evaluation of Responses in Normal-Hearing Young Adults.
– Name: Author
  Label: Authors
  Group: Au
  Data: <searchLink fieldCode="AR" term="%22Lodha%2C+Vidhi%22">Lodha, Vidhi</searchLink><br /><searchLink fieldCode="AR" term="%22Neupane%2C+Anuj+Kumar%22">Neupane, Anuj Kumar</searchLink><i> anujkneupane@gmail.com</i>
– Name: TitleSource
  Label: Source
  Group: Src
  Data: <searchLink fieldCode="JN" term="%22American+Journal+of+Audiology%22">American Journal of Audiology</searchLink>. Dec2022, Vol. 31, p1191-1201. 11p. 2 Charts, 2 Graphs.
– Name: Subject
  Label: Subject Terms
  Group: Su
  Data: *<searchLink fieldCode="DE" term="%22Hearing%22">Hearing</searchLink><br />*<searchLink fieldCode="DE" term="%22Data+analysis%22">Data analysis</searchLink><br /><searchLink fieldCode="DE" term="%22Evoked+potentials+%28Electrophysiology%29%22">Evoked potentials (Electrophysiology)</searchLink><br /><searchLink fieldCode="DE" term="%22Statistics%22">Statistics</searchLink><br /><searchLink fieldCode="DE" term="%22Muscle+contraction%22">Muscle contraction</searchLink><br /><searchLink fieldCode="DE" term="%22Statistical+reliability%22">Statistical reliability</searchLink><br /><searchLink fieldCode="DE" term="%22Research+evaluation%22">Research evaluation</searchLink><br /><searchLink fieldCode="DE" term="%22Intraclass+correlation%22">Intraclass correlation</searchLink><br /><searchLink fieldCode="DE" term="%22Descriptive+statistics%22">Descriptive statistics</searchLink><br /><searchLink fieldCode="DE" term="%22Acoustic+stimulation%22">Acoustic stimulation</searchLink><br /><searchLink fieldCode="DE" term="%22Neck+muscles%22">Neck muscles</searchLink><br /><searchLink fieldCode="DE" term="%22Sternocleidomastoid+muscle%22">Sternocleidomastoid muscle</searchLink><br /><searchLink fieldCode="DE" term="%22Electromyography%22">Electromyography</searchLink><br /><searchLink fieldCode="DE" term="%22Data+analysis+software%22">Data analysis software</searchLink><br /><searchLink fieldCode="DE" term="%22Friedman+test+%28Statistics%29%22">Friedman test (Statistics)</searchLink>
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Purpose: The study aimed to explore the various parameters of multifrequency narrowband Claus Elberling chirp (NB CE-chirp) evoked cervical vestibular evoked myogenic potentials (cVEMPs) in normal-hearing healthy young adults. The study also attempted to define the optimal frequency tuning characteristic of NB CE-chirp evoked cVEMPs. Method: cVEMP was performed on 26 young healthy adults using four different NB CE-chirps centered at 500, 1000, 2000, and 4000 Hz. The neck torsion method was applied for electrode placement. To have the acute recording, visual feedback of sternocleidomastoid muscle contraction was provided, and electromyography (EMG) scaling was done. Results: cVEMPs were present for 100% across all frequencies except at 4000 Hz. Amplitudes between each pair of frequencies were significantly different for EMG scaled and unscaled conditions. Frequency tuning was observed at 500 Hz regardless of scaling done. Positive peak 1 of cVEMP (P1) latencies showed no differences between frequencies while both negative peak 1 of cVEMP and the complex of positive peak 1 and negative peak 1 of cVEMP (P1N1) interpeak latency values decreased with increasing frequency. Interaural amplitude asymmetry ratio showed no difference between scaled and unscaled amplitudes. Intraclass correlation revealed a range of test--retest reliability across frequencies. EMG unscaled amplitude were having relatively lower test--retest reliability consistently across frequencies Conclusions: Differences in amplitudes between frequencies with a maximum at 500 Hz can be attributed to the low frequency centered saccular response. No differences in P1 were observed. Yet, N1 latency and P1N1 interpeak latency difference gradually shortened with the decrement in the stimulus duration as the stimulation frequency increased. The lower reliability of EMG unscaled amplitude across frequencies supports the need to use EMG scaling to avoid confounding variables related to muscle contraction. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: <i>Copyright of American Journal of Audiology is the property of American Speech-Language-Hearing Association and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=ehh&AN=160628913
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.1044/2022_AJA-22-00073
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 11
        StartPage: 1191
    Subjects:
      – SubjectFull: Hearing
        Type: general
      – SubjectFull: Data analysis
        Type: general
      – SubjectFull: Evoked potentials (Electrophysiology)
        Type: general
      – SubjectFull: Statistics
        Type: general
      – SubjectFull: Muscle contraction
        Type: general
      – SubjectFull: Statistical reliability
        Type: general
      – SubjectFull: Research evaluation
        Type: general
      – SubjectFull: Intraclass correlation
        Type: general
      – SubjectFull: Descriptive statistics
        Type: general
      – SubjectFull: Acoustic stimulation
        Type: general
      – SubjectFull: Neck muscles
        Type: general
      – SubjectFull: Sternocleidomastoid muscle
        Type: general
      – SubjectFull: Electromyography
        Type: general
      – SubjectFull: Data analysis software
        Type: general
      – SubjectFull: Friedman test (Statistics)
        Type: general
    Titles:
      – TitleFull: Multifrequency Narrowband Chirp Evoked Cervical Vestibular Myogenic Potentials: Evaluation of Responses in Normal-Hearing Young Adults.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Lodha, Vidhi
      – PersonEntity:
          Name:
            NameFull: Neupane, Anuj Kumar
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 12
              Text: Dec2022
              Type: published
              Y: 2022
          Identifiers:
            – Type: issn-print
              Value: 10590889
          Numbering:
            – Type: volume
              Value: 31
          Titles:
            – TitleFull: American Journal of Audiology
              Type: main
ResultId 1