Multifrequency Narrowband Chirp Evoked Cervical Vestibular Myogenic Potentials: Evaluation of Responses in Normal-Hearing Young Adults.
Saved in:
| Title: | Multifrequency Narrowband Chirp Evoked Cervical Vestibular Myogenic Potentials: Evaluation of Responses in Normal-Hearing Young Adults. |
|---|---|
| Authors: | Lodha, Vidhi, Neupane, Anuj Kumar anujkneupane@gmail.com |
| Source: | American Journal of Audiology. Dec2022, Vol. 31, p1191-1201. 11p. 2 Charts, 2 Graphs. |
| Subject Terms: | *Hearing, *Data analysis, Evoked potentials (Electrophysiology), Statistics, Muscle contraction, Statistical reliability, Research evaluation, Intraclass correlation, Descriptive statistics, Acoustic stimulation, Neck muscles, Sternocleidomastoid muscle, Electromyography, Data analysis software, Friedman test (Statistics) |
| Abstract: | Purpose: The study aimed to explore the various parameters of multifrequency narrowband Claus Elberling chirp (NB CE-chirp) evoked cervical vestibular evoked myogenic potentials (cVEMPs) in normal-hearing healthy young adults. The study also attempted to define the optimal frequency tuning characteristic of NB CE-chirp evoked cVEMPs. Method: cVEMP was performed on 26 young healthy adults using four different NB CE-chirps centered at 500, 1000, 2000, and 4000 Hz. The neck torsion method was applied for electrode placement. To have the acute recording, visual feedback of sternocleidomastoid muscle contraction was provided, and electromyography (EMG) scaling was done. Results: cVEMPs were present for 100% across all frequencies except at 4000 Hz. Amplitudes between each pair of frequencies were significantly different for EMG scaled and unscaled conditions. Frequency tuning was observed at 500 Hz regardless of scaling done. Positive peak 1 of cVEMP (P1) latencies showed no differences between frequencies while both negative peak 1 of cVEMP and the complex of positive peak 1 and negative peak 1 of cVEMP (P1N1) interpeak latency values decreased with increasing frequency. Interaural amplitude asymmetry ratio showed no difference between scaled and unscaled amplitudes. Intraclass correlation revealed a range of test--retest reliability across frequencies. EMG unscaled amplitude were having relatively lower test--retest reliability consistently across frequencies Conclusions: Differences in amplitudes between frequencies with a maximum at 500 Hz can be attributed to the low frequency centered saccular response. No differences in P1 were observed. Yet, N1 latency and P1N1 interpeak latency difference gradually shortened with the decrement in the stimulus duration as the stimulation frequency increased. The lower reliability of EMG unscaled amplitude across frequencies supports the need to use EMG scaling to avoid confounding variables related to muscle contraction. [ABSTRACT FROM AUTHOR] |
| Copyright of American Journal of Audiology is the property of American Speech-Language-Hearing Association and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Education Research Complete |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: ehh DbLabel: Education Research Complete An: 160628913 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Multifrequency Narrowband Chirp Evoked Cervical Vestibular Myogenic Potentials: Evaluation of Responses in Normal-Hearing Young Adults. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Lodha%2C+Vidhi%22">Lodha, Vidhi</searchLink><br /><searchLink fieldCode="AR" term="%22Neupane%2C+Anuj+Kumar%22">Neupane, Anuj Kumar</searchLink><i> anujkneupane@gmail.com</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22American+Journal+of+Audiology%22">American Journal of Audiology</searchLink>. Dec2022, Vol. 31, p1191-1201. 11p. 2 Charts, 2 Graphs. – Name: Subject Label: Subject Terms Group: Su Data: *<searchLink fieldCode="DE" term="%22Hearing%22">Hearing</searchLink><br />*<searchLink fieldCode="DE" term="%22Data+analysis%22">Data analysis</searchLink><br /><searchLink fieldCode="DE" term="%22Evoked+potentials+%28Electrophysiology%29%22">Evoked potentials (Electrophysiology)</searchLink><br /><searchLink fieldCode="DE" term="%22Statistics%22">Statistics</searchLink><br /><searchLink fieldCode="DE" term="%22Muscle+contraction%22">Muscle contraction</searchLink><br /><searchLink fieldCode="DE" term="%22Statistical+reliability%22">Statistical reliability</searchLink><br /><searchLink fieldCode="DE" term="%22Research+evaluation%22">Research evaluation</searchLink><br /><searchLink fieldCode="DE" term="%22Intraclass+correlation%22">Intraclass correlation</searchLink><br /><searchLink fieldCode="DE" term="%22Descriptive+statistics%22">Descriptive statistics</searchLink><br /><searchLink fieldCode="DE" term="%22Acoustic+stimulation%22">Acoustic stimulation</searchLink><br /><searchLink fieldCode="DE" term="%22Neck+muscles%22">Neck muscles</searchLink><br /><searchLink fieldCode="DE" term="%22Sternocleidomastoid+muscle%22">Sternocleidomastoid muscle</searchLink><br /><searchLink fieldCode="DE" term="%22Electromyography%22">Electromyography</searchLink><br /><searchLink fieldCode="DE" term="%22Data+analysis+software%22">Data analysis software</searchLink><br /><searchLink fieldCode="DE" term="%22Friedman+test+%28Statistics%29%22">Friedman test (Statistics)</searchLink> – Name: Abstract Label: Abstract Group: Ab Data: Purpose: The study aimed to explore the various parameters of multifrequency narrowband Claus Elberling chirp (NB CE-chirp) evoked cervical vestibular evoked myogenic potentials (cVEMPs) in normal-hearing healthy young adults. The study also attempted to define the optimal frequency tuning characteristic of NB CE-chirp evoked cVEMPs. Method: cVEMP was performed on 26 young healthy adults using four different NB CE-chirps centered at 500, 1000, 2000, and 4000 Hz. The neck torsion method was applied for electrode placement. To have the acute recording, visual feedback of sternocleidomastoid muscle contraction was provided, and electromyography (EMG) scaling was done. Results: cVEMPs were present for 100% across all frequencies except at 4000 Hz. Amplitudes between each pair of frequencies were significantly different for EMG scaled and unscaled conditions. Frequency tuning was observed at 500 Hz regardless of scaling done. Positive peak 1 of cVEMP (P1) latencies showed no differences between frequencies while both negative peak 1 of cVEMP and the complex of positive peak 1 and negative peak 1 of cVEMP (P1N1) interpeak latency values decreased with increasing frequency. Interaural amplitude asymmetry ratio showed no difference between scaled and unscaled amplitudes. Intraclass correlation revealed a range of test--retest reliability across frequencies. EMG unscaled amplitude were having relatively lower test--retest reliability consistently across frequencies Conclusions: Differences in amplitudes between frequencies with a maximum at 500 Hz can be attributed to the low frequency centered saccular response. No differences in P1 were observed. Yet, N1 latency and P1N1 interpeak latency difference gradually shortened with the decrement in the stimulus duration as the stimulation frequency increased. The lower reliability of EMG unscaled amplitude across frequencies supports the need to use EMG scaling to avoid confounding variables related to muscle contraction. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of American Journal of Audiology is the property of American Speech-Language-Hearing Association and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=ehh&AN=160628913 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1044/2022_AJA-22-00073 Languages: – Code: eng Text: English PhysicalDescription: Pagination: PageCount: 11 StartPage: 1191 Subjects: – SubjectFull: Hearing Type: general – SubjectFull: Data analysis Type: general – SubjectFull: Evoked potentials (Electrophysiology) Type: general – SubjectFull: Statistics Type: general – SubjectFull: Muscle contraction Type: general – SubjectFull: Statistical reliability Type: general – SubjectFull: Research evaluation Type: general – SubjectFull: Intraclass correlation Type: general – SubjectFull: Descriptive statistics Type: general – SubjectFull: Acoustic stimulation Type: general – SubjectFull: Neck muscles Type: general – SubjectFull: Sternocleidomastoid muscle Type: general – SubjectFull: Electromyography Type: general – SubjectFull: Data analysis software Type: general – SubjectFull: Friedman test (Statistics) Type: general Titles: – TitleFull: Multifrequency Narrowband Chirp Evoked Cervical Vestibular Myogenic Potentials: Evaluation of Responses in Normal-Hearing Young Adults. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Lodha, Vidhi – PersonEntity: Name: NameFull: Neupane, Anuj Kumar IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 12 Text: Dec2022 Type: published Y: 2022 Identifiers: – Type: issn-print Value: 10590889 Numbering: – Type: volume Value: 31 Titles: – TitleFull: American Journal of Audiology Type: main |
| ResultId | 1 |