Distributed De-Icing Approach for Overhead Ground Wires Based on AC Power Supply with Thermodynamic Validation.
Saved in:
| Title: | Distributed De-Icing Approach for Overhead Ground Wires Based on AC Power Supply with Thermodynamic Validation. |
|---|---|
| Authors: | Yi, Yongliang1 (AUTHOR), Xiong, Xiaofu1 (AUTHOR), Yu, Changli1 (AUTHOR), Zhu, Junyu1 (AUTHOR), Wang, Jingang1 (AUTHOR) jingang@cqu.edu.cn |
| Source: | Energies (19961073). May2026, Vol. 19 Issue 10, p2474. 17p. |
| Subject Terms: | *Ice prevention & control, *Reactive power control, *Thermal analysis, *Electronic control, *Melting, *Electric power |
| Abstract: | The accumulation of ice on power lines severely affects the safety of power systems. Conventional ice melting methods suffer from poor flexibility and adaptability, accompanied by high power consumption. As a novel technical approach, distributed ice melting deploys modular and movable ice melting units at key sections of overhead ground wires, which generate heat on site according to the actual icing conditions of icing segments, and imposes high requirements on the miniaturization of ice melting equipment as well as the regulation strategy of ice melting current. This study proposes a distributed ice melting method for overhead ground wires based on AC power supply, which can adjust the current in accordance with the specific demands of wire protection and ice melting for different line sections. The feasibility and effectiveness of the proposed method are verified through thermodynamic simulations and experimental tests. The de-icing method injects power–frequency AC into the overhead ground wire through a Scott transformer combined with a series capacitor reactive power compensation structure, enabling on-demand regulation by adjusting capacitor switching strategies and transformer operating modes. This approach balances efficiency and flexibility. Based on a reactive power compensation capacity current control strategy and thermodynamic analysis, an electro-thermal-fluid field coupling simulation model for the experimental ground wire was developed. The current regulation strategies for different environmental and operating conditions were calculated and validated. The simulation results show that, under different conditions, the adjustable current effective values of the de-icing system in this model range from 101 to 380 A (line maintenance current), 304 to 622 A (critical de-icing current), and 661 to 1121 A (maximum de-icing current). Field tests demonstrate that this method can stably achieve AC de-icing and current control. For the experimental JLB40-150 model ground wire, adjusting the injected current to 350 A enables safe operation under line maintenance conditions, with a limit not exceeding 400 A. This paper provides a more efficient, flexible, controllable, and widely applicable method for the de-icing of overhead ground wires. [ABSTRACT FROM AUTHOR] |
| Database: | Energy & Power Source |
|
Full text is not displayed to guests.
Login for full access.
|
|
| Abstract: | The accumulation of ice on power lines severely affects the safety of power systems. Conventional ice melting methods suffer from poor flexibility and adaptability, accompanied by high power consumption. As a novel technical approach, distributed ice melting deploys modular and movable ice melting units at key sections of overhead ground wires, which generate heat on site according to the actual icing conditions of icing segments, and imposes high requirements on the miniaturization of ice melting equipment as well as the regulation strategy of ice melting current. This study proposes a distributed ice melting method for overhead ground wires based on AC power supply, which can adjust the current in accordance with the specific demands of wire protection and ice melting for different line sections. The feasibility and effectiveness of the proposed method are verified through thermodynamic simulations and experimental tests. The de-icing method injects power–frequency AC into the overhead ground wire through a Scott transformer combined with a series capacitor reactive power compensation structure, enabling on-demand regulation by adjusting capacitor switching strategies and transformer operating modes. This approach balances efficiency and flexibility. Based on a reactive power compensation capacity current control strategy and thermodynamic analysis, an electro-thermal-fluid field coupling simulation model for the experimental ground wire was developed. The current regulation strategies for different environmental and operating conditions were calculated and validated. The simulation results show that, under different conditions, the adjustable current effective values of the de-icing system in this model range from 101 to 380 A (line maintenance current), 304 to 622 A (critical de-icing current), and 661 to 1121 A (maximum de-icing current). Field tests demonstrate that this method can stably achieve AC de-icing and current control. For the experimental JLB40-150 model ground wire, adjusting the injected current to 350 A enables safe operation under line maintenance conditions, with a limit not exceeding 400 A. This paper provides a more efficient, flexible, controllable, and widely applicable method for the de-icing of overhead ground wires. [ABSTRACT FROM AUTHOR] |
|---|---|
| ISSN: | 19961073 |
| DOI: | 10.3390/en19102474 |