A Dual-Factor Defrosting Model for Air-Source Heat Pumps Considering Ambient Temperature and Compressor Frequency.

Saved in:
Bibliographic Details
Title: A Dual-Factor Defrosting Model for Air-Source Heat Pumps Considering Ambient Temperature and Compressor Frequency.
Authors: Xu, Xuyan1 (AUTHOR), Zhang, Tao2 (AUTHOR), Li, Dongming1,2 (AUTHOR), Sun, Wanchun2 (AUTHOR), Wu, Zhijiang2 (AUTHOR), Xu, Yansheng2 (AUTHOR)
Source: Energies (19961073). Jun2026, Vol. 19 Issue 12, p2787. 27p.
Subject Terms: *Atmospheric temperature, *Compressor performance, *Conservation of energy, *Ice formation & growth, *Air source heat pump systems, *Heat pump efficiency, *Prediction models
Abstract: This study presents a novel investigation into the coupled effects of ambient temperature and compressor frequency on frosting behavior and thermal performance of inverter-driven air-source heat pumps (ASHPs) under low-temperature, high-humidity conditions. Unlike previous studies that focused on single environmental parameters, this work systematically explores temperature–frequency coupling. Experiments were conducted on a 3-HP DC inverter low-ambient-temperature ASHP unit using a multi-climate simulated enthalpy difference test bench. Single-factor analysis shows that frosting is most severe at 0 °C, where the frost growth rate peaks. Regarding compressor frequency, the coefficient of performance (COP) initially increases and then decreases with frequency. The maximum COP occurs near 45 Hz, representing the optimal energy efficiency balance in this experimental system. Sensitivity analysis demonstrates that relative humidity contributes less than 5% to performance degradation at the critical 10% COP reduction point. Thus, ambient temperature and compressor frequency are the core determinants of defrosting timing. A dual-factor prediction model for the critical defrosting air-to-coil temperature difference (∆T) is developed using temperature (t) and frequency (f) as independent variables. Validation confirms that the model maintains prediction error within 10% under both single-factor and multi-factor coupling conditions. Collectively, this research quantifies the coupled effects of ambient temperature and compressor frequency on frosting performance and provides a novel theoretical framework for precise defrosting control in inverter ASHPs based on performance attenuation. [ABSTRACT FROM AUTHOR]
Database: Energy & Power Source
Full text is not displayed to guests.
Description
Abstract:This study presents a novel investigation into the coupled effects of ambient temperature and compressor frequency on frosting behavior and thermal performance of inverter-driven air-source heat pumps (ASHPs) under low-temperature, high-humidity conditions. Unlike previous studies that focused on single environmental parameters, this work systematically explores temperature–frequency coupling. Experiments were conducted on a 3-HP DC inverter low-ambient-temperature ASHP unit using a multi-climate simulated enthalpy difference test bench. Single-factor analysis shows that frosting is most severe at 0 °C, where the frost growth rate peaks. Regarding compressor frequency, the coefficient of performance (COP) initially increases and then decreases with frequency. The maximum COP occurs near 45 Hz, representing the optimal energy efficiency balance in this experimental system. Sensitivity analysis demonstrates that relative humidity contributes less than 5% to performance degradation at the critical 10% COP reduction point. Thus, ambient temperature and compressor frequency are the core determinants of defrosting timing. A dual-factor prediction model for the critical defrosting air-to-coil temperature difference (∆T) is developed using temperature (t) and frequency (f) as independent variables. Validation confirms that the model maintains prediction error within 10% under both single-factor and multi-factor coupling conditions. Collectively, this research quantifies the coupled effects of ambient temperature and compressor frequency on frosting performance and provides a novel theoretical framework for precise defrosting control in inverter ASHPs based on performance attenuation. [ABSTRACT FROM AUTHOR]
ISSN:19961073
DOI:10.3390/en19122787