Bibliographic Details
| Title: |
Experience with a modified Macintosh laryngoscope as a video laryngoscope adapted to a USB camera and cellphone. |
| Authors: |
Palacios-Ríos, Dionicio1, Nava-Vázquez, Roberto E.1 rob_env@hotmail.com, Rodríguez-Rodríguez, Nora H.1, López-Cabrera, Norma G.1, González-Cordero, Gustavo1 |
| Source: |
Medicina Universitaria. 2019, Vol. 21 Issue 2, p57-62. 6p. |
| Subjects: |
LARYNGOSCOPY, TRACHEA intubation, AIRWAY (Anatomy), CAMERAS, CELL phones, ANESTHESIOLOGISTS, GLOTTIS |
| Geographic Terms: |
TURKEY |
| Abstract: |
Introduction: Management of the airway is one of the challenges in anesthesiology; multiple devices and techniques have been developed to manage it, preventing a catastrophic outcome for the patient in different scenarios. Objective: The objective of the study was to demonstrate that our modified laryngoscope, using a cell phone as a screen monitor, is useful and safe in the management of the adult patient's airway. Materials and methods: This was a descriptive, observational, and prospective study, using the modified laryngoscope for intubation in 139 elective patients, with airway check-up, intubation time measurement, number of attempts, observed Cormack-Lehane, percentage of glottis observed (POGO) scale, and adverse events registry. Results: There were 138 patients with successful intubations and one failure. Of these, 66.1% were female, and 33.9% were male, 92% were intubated on the first attempt. About 61% were intubated in 30 s or less and 35% in <1 min, visualization of the glottal ring was 82%, 72% of which were recorded as Cormack-Lehane I, and with POGOs of 100%, the burp maneuver was used to assist in 38%. Conclusions: The device proved to be useful and safe in the management of the patient's airway, with a success rate of 92% in the first attempt. [ABSTRACT FROM AUTHOR] |
|
Copyright of Medicina Universitaria is the property of Medicina Universitaria and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
| Database: |
MedicLatina |