Experience with a modified Macintosh laryngoscope as a video laryngoscope adapted to a USB camera and cellphone.

Saved in:
Bibliographic Details
Title: Experience with a modified Macintosh laryngoscope as a video laryngoscope adapted to a USB camera and cellphone.
Authors: Palacios-Ríos, Dionicio1, Nava-Vázquez, Roberto E.1 rob_env@hotmail.com, Rodríguez-Rodríguez, Nora H.1, López-Cabrera, Norma G.1, González-Cordero, Gustavo1
Source: Medicina Universitaria. 2019, Vol. 21 Issue 2, p57-62. 6p.
Subjects: LARYNGOSCOPY, TRACHEA intubation, AIRWAY (Anatomy), CAMERAS, CELL phones, ANESTHESIOLOGISTS, GLOTTIS
Geographic Terms: TURKEY
Abstract: Introduction: Management of the airway is one of the challenges in anesthesiology; multiple devices and techniques have been developed to manage it, preventing a catastrophic outcome for the patient in different scenarios. Objective: The objective of the study was to demonstrate that our modified laryngoscope, using a cell phone as a screen monitor, is useful and safe in the management of the adult patient's airway. Materials and methods: This was a descriptive, observational, and prospective study, using the modified laryngoscope for intubation in 139 elective patients, with airway check-up, intubation time measurement, number of attempts, observed Cormack-Lehane, percentage of glottis observed (POGO) scale, and adverse events registry. Results: There were 138 patients with successful intubations and one failure. Of these, 66.1% were female, and 33.9% were male, 92% were intubated on the first attempt. About 61% were intubated in 30 s or less and 35% in <1 min, visualization of the glottal ring was 82%, 72% of which were recorded as Cormack-Lehane I, and with POGOs of 100%, the burp maneuver was used to assist in 38%. Conclusions: The device proved to be useful and safe in the management of the patient's airway, with a success rate of 92% in the first attempt. [ABSTRACT FROM AUTHOR]
Copyright of Medicina Universitaria is the property of Medicina Universitaria and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: MedicLatina
FullText Text:
  Availability: 0
Header DbId: lth
DbLabel: MedicLatina
An: 144608943
AccessLevel: 6
PubType: Academic Journal
PubTypeId: academicJournal
PreciseRelevancyScore: 0
IllustrationInfo
Items – Name: Title
  Label: Title
  Group: Ti
  Data: Experience with a modified Macintosh laryngoscope as a video laryngoscope adapted to a USB camera and cellphone.
– Name: Author
  Label: Authors
  Group: Au
  Data: &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Palacios-R&#237;os%2C+Dionicio%22&quot;&gt;Palacios-R&#237;os, Dionicio&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Nava-V&#225;zquez%2C+Roberto+E%2E%22&quot;&gt;Nava-V&#225;zquez, Roberto E.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;i&gt; rob_env@hotmail.com&lt;/i&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Rodr&#237;guez-Rodr&#237;guez%2C+Nora+H%2E%22&quot;&gt;Rodr&#237;guez-Rodr&#237;guez, Nora H.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22L&#243;pez-Cabrera%2C+Norma+G%2E%22&quot;&gt;L&#243;pez-Cabrera, Norma G.&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Gonz&#225;lez-Cordero%2C+Gustavo%22&quot;&gt;Gonz&#225;lez-Cordero, Gustavo&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt;
– Name: TitleSource
  Label: Source
  Group: Src
  Data: &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Medicina+Universitaria%22&quot;&gt;Medicina Universitaria&lt;/searchLink&gt;. 2019, Vol. 21 Issue 2, p57-62. 6p.
– Name: Subject
  Label: Subjects
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22LARYNGOSCOPY%22&quot;&gt;LARYNGOSCOPY&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22TRACHEA+intubation%22&quot;&gt;TRACHEA intubation&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22AIRWAY+%28Anatomy%29%22&quot;&gt;AIRWAY (Anatomy)&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22CAMERAS%22&quot;&gt;CAMERAS&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22CELL+phones%22&quot;&gt;CELL phones&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22ANESTHESIOLOGISTS%22&quot;&gt;ANESTHESIOLOGISTS&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22GLOTTIS%22&quot;&gt;GLOTTIS&lt;/searchLink&gt;
– Name: SubjectGeographic
  Label: Geographic Terms
  Group: Su
  Data: &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22TURKEY%22&quot;&gt;TURKEY&lt;/searchLink&gt;
– Name: Abstract
  Label: Abstract
  Group: Ab
  Data: Introduction: Management of the airway is one of the challenges in anesthesiology; multiple devices and techniques have been developed to manage it, preventing a catastrophic outcome for the patient in different scenarios. Objective: The objective of the study was to demonstrate that our modified laryngoscope, using a cell phone as a screen monitor, is useful and safe in the management of the adult patient&#39;s airway. Materials and methods: This was a descriptive, observational, and prospective study, using the modified laryngoscope for intubation in 139 elective patients, with airway check-up, intubation time measurement, number of attempts, observed Cormack-Lehane, percentage of glottis observed (POGO) scale, and adverse events registry. Results: There were 138 patients with successful intubations and one failure. Of these, 66.1% were female, and 33.9% were male, 92% were intubated on the first attempt. About 61% were intubated in 30 s or less and 35% in &lt;1 min, visualization of the glottal ring was 82%, 72% of which were recorded as Cormack-Lehane I, and with POGOs of 100%, the burp maneuver was used to assist in 38%. Conclusions: The device proved to be useful and safe in the management of the patient&#39;s airway, with a success rate of 92% in the first attempt. [ABSTRACT FROM AUTHOR]
– Name: AbstractSuppliedCopyright
  Label:
  Group: Ab
  Data: &lt;i&gt;Copyright of Medicina Universitaria is the property of Medicina Universitaria and its content may not be copied or emailed to multiple sites without the copyright holder&#39;s express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.&lt;/i&gt; (Copyright applies to all Abstracts.)
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=lth&AN=144608943
RecordInfo BibRecord:
  BibEntity:
    Identifiers:
      – Type: doi
        Value: 10.24875/RMU.19000067
    Languages:
      – Code: eng
        Text: English
    PhysicalDescription:
      Pagination:
        PageCount: 6
        StartPage: 57
    Subjects:
      – SubjectFull: LARYNGOSCOPY
        Type: general
      – SubjectFull: TRACHEA intubation
        Type: general
      – SubjectFull: AIRWAY (Anatomy)
        Type: general
      – SubjectFull: CAMERAS
        Type: general
      – SubjectFull: CELL phones
        Type: general
      – SubjectFull: ANESTHESIOLOGISTS
        Type: general
      – SubjectFull: GLOTTIS
        Type: general
      – SubjectFull: TURKEY
        Type: general
    Titles:
      – TitleFull: Experience with a modified Macintosh laryngoscope as a video laryngoscope adapted to a USB camera and cellphone.
        Type: main
  BibRelationships:
    HasContributorRelationships:
      – PersonEntity:
          Name:
            NameFull: Palacios-Ríos, Dionicio
      – PersonEntity:
          Name:
            NameFull: Nava-Vázquez, Roberto E.
      – PersonEntity:
          Name:
            NameFull: Rodríguez-Rodríguez, Nora H.
      – PersonEntity:
          Name:
            NameFull: López-Cabrera, Norma G.
      – PersonEntity:
          Name:
            NameFull: González-Cordero, Gustavo
    IsPartOfRelationships:
      – BibEntity:
          Dates:
            – D: 01
              M: 04
              Text: 2019
              Type: published
              Y: 2019
          Identifiers:
            – Type: issn-print
              Value: 16655796
          Numbering:
            – Type: volume
              Value: 21
            – Type: issue
              Value: 2
          Titles:
            – TitleFull: Medicina Universitaria
              Type: main
ResultId 1