Prototipo de estimulador electrónico para ser utilizado en colostomía.
Saved in:
| Title: | Prototipo de estimulador electrónico para ser utilizado en colostomía. |
|---|---|
| Authors: | Martínez, M. Sagahón1, Rojas, C. Villalobos1, Awad, R. A.1 awadrichard@iserve.net.mx |
| Source: | Revista Mexicana de Ingeniería Biomédica. dec2009, Vol. 30 Issue 2, p109-118. 10p. 2 Black and White Photographs, 4 Diagrams, 1 Chart, 3 Graphs. |
| Subjects: | COLOSTOMY, PRESSURE transducers, COLON surgery, ANUS, RECTUM |
| Abstract (English): | The need to rehabilitate the muscles of a colostomy through electrical stimulation, using a portable instrument, to regaining contingency is of great necessity for colostomized patients. In 1994, Awad and Luna developed a straight-anal simulator that shows the power and pressure variations in the rectum and the internal anal sphincter. In 2000, Riedy et al. used a battery-powered stimulator to stimulate the sphincter muscle, with a stream of 0-100 mA and 35 Hz. In 2005, Awad et al. They developed a virtual simulator of colon mechanics with computer programs. In 2006, Awad and Sagahón developed a device to stimulate the visceral smooth muscle in a colostomy for to regaining voluntary continent. The purpose was to design and build a portable 3 variables electronic stimulator (pressure, voltage and current). We design a prototype portable stimulator of 3 variables controlled by a pressure sensor. The current and voltage of the equipment were calibrated using a digital multimeter, and frequency using a digital oscilloscope. The design, development and assembly of the electronic stimulator will be used in the experimental animal colostomy model, evaluating and controlling pressure, voltage and frequency variables. [ABSTRACT FROM AUTHOR] |
| Abstract (Spanish): | La necesidad de rehabilitar los músculos de una colostomía mediante estímulos eléctricos, por medio de un instrumento portátil para volverla continente es de gran necesidad para pacientes colostomizados. En 1994, Awad y Luna desarrollaron un simulador recto-anal que muestra las variaciones eléctricas y de presión en el recto y en el esfínter anal interno. En 2000 Riedy, y cols. Usaron un dispositivo de batería para estimular el esfínter, mediante una corriente de 0-100 mA y 35 Hz. En 2005 Awad y cols. desarrollaron un simulador virtual de la mecánica del colon con programas computacionales. En 2006 Awad y Sagahón desarrollaron un dispositivo para estimular el músculo liso visceral en una colostomía para volverla continente a voluntad. El propósito de este trabajo fue diseñar y armar un estimulador electrónico portátil de 3 variables (presión, voltaje y corriente). Se diseñó un prototipo de estimulador de 3 variables controlado mediante un sensor de presión. La corriente y el voltaje del equipo fueron calibrados mediante un multímetro digital, y la frecuencia mediante un osciloscopio digital. El diseño, desarrollo y armado del estimulador electrónico servirá para utilizarlo en la colostomía del modelo experimental animal, valorando y controlando las variables de presión, voltaje y frecuencia. [ABSTRACT FROM AUTHOR] |
| Copyright of Revista Mexicana de Ingeniería Biomédica is the property of Sociedad Mexicana de Ingenieria Biomedica, A.C. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | MedicLatina |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: lth DbLabel: MedicLatina An: 52094549 AccessLevel: 6 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: Prototipo de estimulador electrónico para ser utilizado en colostomía. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AR" term="%22Martínez%2C+M%2E+Sagahón%22">Martínez, M. Sagahón</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Rojas%2C+C%2E+Villalobos%22">Rojas, C. Villalobos</searchLink><relatesTo>1</relatesTo><br /><searchLink fieldCode="AR" term="%22Awad%2C+R%2E+A%2E%22">Awad, R. A.</searchLink><relatesTo>1</relatesTo><i> awadrichard@iserve.net.mx</i> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%22Revista+Mexicana+de+Ingeniería+Biomédica%22">Revista Mexicana de Ingeniería Biomédica</searchLink>. dec2009, Vol. 30 Issue 2, p109-118. 10p. 2 Black and White Photographs, 4 Diagrams, 1 Chart, 3 Graphs. – Name: Subject Label: Subjects Group: Su Data: <searchLink fieldCode="DE" term="%22COLOSTOMY%22">COLOSTOMY</searchLink><br /><searchLink fieldCode="DE" term="%22PRESSURE+transducers%22">PRESSURE transducers</searchLink><br /><searchLink fieldCode="DE" term="%22COLON+surgery%22">COLON surgery</searchLink><br /><searchLink fieldCode="DE" term="%22ANUS%22">ANUS</searchLink><br /><searchLink fieldCode="DE" term="%22RECTUM%22">RECTUM</searchLink> – Name: Abstract Label: Abstract (English) Group: Ab Data: The need to rehabilitate the muscles of a colostomy through electrical stimulation, using a portable instrument, to regaining contingency is of great necessity for colostomized patients. In 1994, Awad and Luna developed a straight-anal simulator that shows the power and pressure variations in the rectum and the internal anal sphincter. In 2000, Riedy et al. used a battery-powered stimulator to stimulate the sphincter muscle, with a stream of 0-100 mA and 35 Hz. In 2005, Awad et al. They developed a virtual simulator of colon mechanics with computer programs. In 2006, Awad and Sagahón developed a device to stimulate the visceral smooth muscle in a colostomy for to regaining voluntary continent. The purpose was to design and build a portable 3 variables electronic stimulator (pressure, voltage and current). We design a prototype portable stimulator of 3 variables controlled by a pressure sensor. The current and voltage of the equipment were calibrated using a digital multimeter, and frequency using a digital oscilloscope. The design, development and assembly of the electronic stimulator will be used in the experimental animal colostomy model, evaluating and controlling pressure, voltage and frequency variables. [ABSTRACT FROM AUTHOR] – Name: Abstract Label: Abstract (Spanish) Group: Ab Data: La necesidad de rehabilitar los músculos de una colostomía mediante estímulos eléctricos, por medio de un instrumento portátil para volverla continente es de gran necesidad para pacientes colostomizados. En 1994, Awad y Luna desarrollaron un simulador recto-anal que muestra las variaciones eléctricas y de presión en el recto y en el esfínter anal interno. En 2000 Riedy, y cols. Usaron un dispositivo de batería para estimular el esfínter, mediante una corriente de 0-100 mA y 35 Hz. En 2005 Awad y cols. desarrollaron un simulador virtual de la mecánica del colon con programas computacionales. En 2006 Awad y Sagahón desarrollaron un dispositivo para estimular el músculo liso visceral en una colostomía para volverla continente a voluntad. El propósito de este trabajo fue diseñar y armar un estimulador electrónico portátil de 3 variables (presión, voltaje y corriente). Se diseñó un prototipo de estimulador de 3 variables controlado mediante un sensor de presión. La corriente y el voltaje del equipo fueron calibrados mediante un multímetro digital, y la frecuencia mediante un osciloscopio digital. El diseño, desarrollo y armado del estimulador electrónico servirá para utilizarlo en la colostomía del modelo experimental animal, valorando y controlando las variables de presión, voltaje y frecuencia. [ABSTRACT FROM AUTHOR] – Name: AbstractSuppliedCopyright Label: Group: Ab Data: <i>Copyright of Revista Mexicana de Ingeniería Biomédica is the property of Sociedad Mexicana de Ingenieria Biomedica, A.C. and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract.</i> (Copyright applies to all Abstracts.) |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=lth&AN=52094549 |
| RecordInfo | BibRecord: BibEntity: Languages: – Code: spa Text: Spanish PhysicalDescription: Pagination: PageCount: 10 StartPage: 109 Subjects: – SubjectFull: COLOSTOMY Type: general – SubjectFull: PRESSURE transducers Type: general – SubjectFull: COLON surgery Type: general – SubjectFull: ANUS Type: general – SubjectFull: RECTUM Type: general Titles: – TitleFull: Prototipo de estimulador electrónico para ser utilizado en colostomía. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Martínez, M. Sagahón – PersonEntity: Name: NameFull: Rojas, C. Villalobos – PersonEntity: Name: NameFull: Awad, R. A. IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 12 Text: dec2009 Type: published Y: 2009 Identifiers: – Type: issn-print Value: 01889532 Numbering: – Type: volume Value: 30 – Type: issue Value: 2 Titles: – TitleFull: Revista Mexicana de Ingeniería Biomédica Type: main |
| ResultId | 1 |