The use of computerised glow curve analysis will optimise personal thermoluminescence dosimetry measurements. Opposing the proposition.
Saved in:
| Title: | The use of computerised glow curve analysis will optimise personal thermoluminescence dosimetry measurements. Opposing the proposition. |
|---|---|
| Authors: | Pradhan AS; Bhabha Atomic Research Centre, Mumbai, India., Yoder RC |
| Source: | Radiation protection dosimetry [Radiat Prot Dosimetry] 2002; Vol. 102 (3), pp. 274-7. |
| Publication Type: | Comment; Journal Article |
| Journal Info: | Publisher: Oxford University Press Country of Publication: England NLM ID: 8109958 Publication Model: Print Cited Medium: Print ISSN: 0144-8420 (Print) Linking ISSN: 01448420 NLM ISO Abbreviation: Radiat Prot Dosimetry Subsets: MEDLINE |
| Database: | MEDLINE Ultimate |
| FullText | Links: – Type: pdflink Text: Availability: 0 |
|---|---|
| Header | DbId: mdl DbLabel: MEDLINE Ultimate An: 12430967 AccessLevel: 2 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: The use of computerised glow curve analysis will optimise personal thermoluminescence dosimetry measurements. Opposing the proposition. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Pradhan+AS%22">Pradhan AS</searchLink>; Bhabha Atomic Research Centre, Mumbai, India.<br /><searchLink fieldCode="AU" term="%22Yoder+RC%22">Yoder RC</searchLink> – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%228109958%22">Radiation protection dosimetry</searchLink> [Radiat Prot Dosimetry] 2002; Vol. 102 (3), pp. 274-7. – Name: TypePub Label: Publication Type Group: TypPub Data: Comment; Journal Article – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Oxford+University+Press%22">Oxford University Press </searchLink><i>Country of Publication: </i>England <i>NLM ID: </i>8109958 <i>Publication Model: </i>Print <i>Cited Medium: </i>Print <i>ISSN: </i>0144-8420 (Print) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2201448420%22">01448420 </searchLink><i>NLM ISO Abbreviation: </i>Radiat Prot Dosimetry <i>Subsets: </i>MEDLINE |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=mdl&AN=12430967 |
| RecordInfo | BibRecord: BibEntity: Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 274 Titles: – TitleFull: The use of computerised glow curve analysis will optimise personal thermoluminescence dosimetry measurements. Opposing the proposition. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Pradhan AS – PersonEntity: Name: NameFull: Yoder RC IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 01 Text: 2002 Type: published Y: 2002 Identifiers: – Type: issn-print Value: 0144-8420 Numbering: – Type: volume Value: 102 – Type: issue Value: 3 Titles: – TitleFull: Radiation protection dosimetry Type: main |
| ResultId | 1 |