A method for accuracy of placement analysis on radiolucent polyether-ether-keton facial implants: A case series.
Saved in:
| Title: | A method for accuracy of placement analysis on radiolucent polyether-ether-keton facial implants: A case series. |
|---|---|
| Authors: | Kortman MCP; University of Twente, Technical Medical Centre, Multi-Modality Medical Imaging (M3i), Faculty of Science & Technology, Enschede, the Netherlands., Jansma J; Dpt of Oral and Maxillofacial Surgery, Martini Hospital, Groningen, the Netherlands., Schepers RH; Dpt of Oral and Maxillofacial Surgery, Martini Hospital, Groningen, the Netherlands., Slump CH; University of Twente, Technical Medical Centre, Robotics and Mechatronics, Faculty of Electrical Engineering Mathematics and Computer Science, Enschede, the Netherlands., Merema BJ; 3D Lab, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands; Dpt of Oral and Maxillofacial Surgery, University of Groningen, University Medical Centre Groningen, Groningen, the Netherlands., Kraeima J; 3D Lab, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands; Dpt of Oral and Maxillofacial Surgery, University of Groningen, University Medical Centre Groningen, Groningen, the Netherlands. Electronic address: j.kraeima@umcg.nl. |
| Source: | Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery [J Craniomaxillofac Surg] 2024 Oct; Vol. 52 (10), pp. 1082-1087. Date of Electronic Publication: 2024 Jun 15. |
| Publication Type: | Journal Article; Case Reports |
| Journal Info: | Publisher: Elsevier Country of Publication: Scotland NLM ID: 8704309 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1878-4119 (Electronic) Linking ISSN: 10105182 NLM ISO Abbreviation: J Craniomaxillofac Surg Subsets: MEDLINE |
| Database: | MEDLINE Ultimate |
| FullText | Text: Availability: 0 |
|---|---|
| Header | DbId: mdl DbLabel: MEDLINE Ultimate An: 39004536 AccessLevel: 2 PubType: Academic Journal PubTypeId: academicJournal PreciseRelevancyScore: 0 |
| IllustrationInfo | |
| Items | – Name: Title Label: Title Group: Ti Data: A method for accuracy of placement analysis on radiolucent polyether-ether-keton facial implants: A case series. – Name: Author Label: Authors Group: Au Data: <searchLink fieldCode="AU" term="%22Kortman+MCP%22">Kortman MCP</searchLink>; University of Twente, Technical Medical Centre, Multi-Modality Medical Imaging (M3i), Faculty of Science & Technology, Enschede, the Netherlands.<br /><searchLink fieldCode="AU" term="%22Jansma+J%22">Jansma J</searchLink>; Dpt of Oral and Maxillofacial Surgery, Martini Hospital, Groningen, the Netherlands.<br /><searchLink fieldCode="AU" term="%22Schepers+RH%22">Schepers RH</searchLink>; Dpt of Oral and Maxillofacial Surgery, Martini Hospital, Groningen, the Netherlands.<br /><searchLink fieldCode="AU" term="%22Slump+CH%22">Slump CH</searchLink>; University of Twente, Technical Medical Centre, Robotics and Mechatronics, Faculty of Electrical Engineering Mathematics and Computer Science, Enschede, the Netherlands.<br /><searchLink fieldCode="AU" term="%22Merema+BJ%22">Merema BJ</searchLink>; 3D Lab, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands; Dpt of Oral and Maxillofacial Surgery, University of Groningen, University Medical Centre Groningen, Groningen, the Netherlands.<br /><searchLink fieldCode="AU" term="%22Kraeima+J%22">Kraeima J</searchLink>; 3D Lab, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands; Dpt of Oral and Maxillofacial Surgery, University of Groningen, University Medical Centre Groningen, Groningen, the Netherlands. Electronic address: j.kraeima@umcg.nl. – Name: TitleSource Label: Source Group: Src Data: <searchLink fieldCode="JN" term="%228704309%22">Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery</searchLink> [J Craniomaxillofac Surg] 2024 Oct; Vol. 52 (10), pp. 1082-1087. <i>Date of Electronic Publication: </i>2024 Jun 15. – Name: TypePub Label: Publication Type Group: TypPub Data: Journal Article; Case Reports – Name: TitleSource Label: Journal Info Group: Src Data: <i>Publisher: </i><searchLink fieldCode="PB" term="%22Elsevier%22">Elsevier </searchLink><i>Country of Publication: </i>Scotland <i>NLM ID: </i>8704309 <i>Publication Model: </i>Print-Electronic <i>Cited Medium: </i>Internet <i>ISSN: </i>1878-4119 (Electronic) <i>Linking ISSN: </i><searchLink fieldCode="IS" term="%2210105182%22">10105182 </searchLink><i>NLM ISO Abbreviation: </i>J Craniomaxillofac Surg <i>Subsets: </i>MEDLINE |
| PLink | https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&db=mdl&AN=39004536 |
| RecordInfo | BibRecord: BibEntity: Identifiers: – Type: doi Value: 10.1016/j.jcms.2024.06.009 Languages: – Code: eng Text: English PhysicalDescription: Pagination: StartPage: 1082 Titles: – TitleFull: A method for accuracy of placement analysis on radiolucent polyether-ether-keton facial implants: A case series. Type: main BibRelationships: HasContributorRelationships: – PersonEntity: Name: NameFull: Kortman MCP – PersonEntity: Name: NameFull: Jansma J – PersonEntity: Name: NameFull: Schepers RH – PersonEntity: Name: NameFull: Slump CH – PersonEntity: Name: NameFull: Merema BJ – PersonEntity: Name: NameFull: Kraeima J IsPartOfRelationships: – BibEntity: Dates: – D: 01 M: 10 Text: 2024 Oct Type: published Y: 2024 Identifiers: – Type: issn-electronic Value: 1878-4119 Numbering: – Type: volume Value: 52 – Type: issue Value: 10 Titles: – TitleFull: Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery Type: main |
| ResultId | 1 |