High-temporal-resolution on-site multiplex biomarker monitoring in small animals using microfluidic digital ELISA.

Saved in:
Bibliographic Details
Title: High-temporal-resolution on-site multiplex biomarker monitoring in small animals using microfluidic digital ELISA.
Authors: Song Y; Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, 11201, USA; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA. Electronic address: ys6780@nyu.edu., Stephens AD; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA; Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, University of Michigan Health System, Ann Arbor, MI, 48109, USA., Deng H; Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, University of Michigan Health System, Ann Arbor, MI, 48109, USA; Department of Anesthesiology, Third Xiangya Hospital, Central South University, Changsha, Hunan, 410013, PR China., Füredi AD; Department of Biomedical Engineering, New York University, Brooklyn, NY, 11201, USA., Su SH; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA., Ye Y; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA., Chen Y; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA., Newstead M; Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, University of Michigan Health System, Ann Arbor, MI, 48109, USA., Yin Q; Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, 11201, USA., Lehto J; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA., Fahim Z; Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, University of Michigan Health System, Ann Arbor, MI, 48109, USA., Singer BH; Department of Internal Medicine, Division of Pulmonary and Critical Care Medicine, University of Michigan Health System, Ann Arbor, MI, 48109, USA; Weil Institute for Critical Care Research & Innovation, Ann Arbor, MI, 48109, USA. Electronic address: singerb@med.umich.edu., Kurabayashi K; Department of Mechanical and Aerospace Engineering, New York University, Brooklyn, NY, 11201, USA; Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA; Weil Institute for Critical Care Research & Innovation, Ann Arbor, MI, 48109, USA; Department of Chemical and Biomolecular Engineering, New York University, Brooklyn, NY, 11201, USA. Electronic address: katsuo.k@nyu.edu.
Source: Biosensors & bioelectronics [Biosens Bioelectron] 2025 Nov 15; Vol. 288, pp. 117820. Date of Electronic Publication: 2025 Jul 24.
Publication Type: Journal Article
Journal Info: Publisher: Elsevier Advanced Technology Country of Publication: England NLM ID: 9001289 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1873-4235 (Electronic) Linking ISSN: 09565663 NLM ISO Abbreviation: Biosens Bioelectron Subsets: MEDLINE
Database: MEDLINE Ultimate
Description
ISSN:1873-4235
DOI:10.1016/j.bios.2025.117820