Early functional results using the nitibond prosthesis in stapes surgery.
Saved in:
| Title: | Early functional results using the nitibond prosthesis in stapes surgery. |
|---|---|
| Authors: | Canu, Giuseppina (AUTHOR), Lauretani, Fulvio (AUTHOR), Russo, Francesca Yoshie (AUTHOR), Ferrary, Evelyne (AUTHOR), Lamas, Georges (AUTHOR), Sterkers, Olivier (AUTHOR), De Seta, Daniele (AUTHOR), Bernardeschi, Daniele (AUTHOR) |
| Source: | Acta Oto-Laryngologica. Mar2017, Vol. 137 Issue 3, p259-264. 6p. |
| Subjects: | Analysis of covariance, Analysis of variance, Audiometry, Chi-squared test, Ear surgery, Hard of hearing people, Longitudinal method, Scientific observation, Probability theory, Rehabilitation, Pre-tests & post-tests, Repeated measures design, Data analysis software, Descriptive statistics |
| Abstract: | Conclusion: The NiTiBONDV® prosthesis allows early results to be obtained similar to those with a manually crimped prosthesis fitted by experienced surgeons, thus reducing the learning curve in this critical step of the procedure. Objective: To analyze the 1-month results using the nitinol NiTiBONDV® prosthesis in primary otosclerosis surgery and to compare the results with those obtained with fully fluoroplastic or fully titanium pistons. Materials and methods: Fifty consecutive cases operated on with the NiTiBONDV® prosthesis (nitinol group) were compared with 50 cases operated on with a fully fluoroplastic piston (fluoroplastic group), and with 131 cases operated on with a fully titanium piston (first titanium group), and also with 50 cases operated on with the same titanium piston just before using the NiTiBONDV® piston (last titanium group). Pure-tone and speech audiometry was performed 1 month after surgery for the nitinol group. Comparison was made between the early hearing results of the four groups. Results: The mean air-bone gap closure for the nitinol group was 16 ± 1.0 dB (mean ± SEM, n=50); an air-bone gap of<15 dB and<10 dB was obtained in 100% and 84% of cases, respectively. These hearing results were similar to the last titanium group and significantly better than those observed in the fluoroplastic and first titanium groups. [ABSTRACT FROM AUTHOR] |
| Copyright of Acta Oto-Laryngologica is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) | |
| Database: | Psychology and Behavioral Sciences Collection |
|
Full text is not displayed to guests.
Login for full access.
|
|
| Abstract: | Conclusion: The NiTiBONDV® prosthesis allows early results to be obtained similar to those with a manually crimped prosthesis fitted by experienced surgeons, thus reducing the learning curve in this critical step of the procedure. Objective: To analyze the 1-month results using the nitinol NiTiBONDV® prosthesis in primary otosclerosis surgery and to compare the results with those obtained with fully fluoroplastic or fully titanium pistons. Materials and methods: Fifty consecutive cases operated on with the NiTiBONDV® prosthesis (nitinol group) were compared with 50 cases operated on with a fully fluoroplastic piston (fluoroplastic group), and with 131 cases operated on with a fully titanium piston (first titanium group), and also with 50 cases operated on with the same titanium piston just before using the NiTiBONDV® piston (last titanium group). Pure-tone and speech audiometry was performed 1 month after surgery for the nitinol group. Comparison was made between the early hearing results of the four groups. Results: The mean air-bone gap closure for the nitinol group was 16 ± 1.0 dB (mean ± SEM, n=50); an air-bone gap of<15 dB and<10 dB was obtained in 100% and 84% of cases, respectively. These hearing results were similar to the last titanium group and significantly better than those observed in the fluoroplastic and first titanium groups. [ABSTRACT FROM AUTHOR] |
|---|---|
| ISSN: | 00016489 |
| DOI: | 10.1080/00016489.2016.1247499 |