Uncovering auditory evoked potentials from cochlear implant users with independent component analysis.

Saved in:
Bibliographic Details
Title: Uncovering auditory evoked potentials from cochlear implant users with independent component analysis.
Authors: Viola, Filipa C. (AUTHOR), Thorne, Jeremy D. (AUTHOR), Bleeck, Stefan (AUTHOR), Eyles, Julie (AUTHOR), Debener, Stefan (AUTHOR)
Source: Psychophysiology. Nov2011, Vol. 48 Issue 11, p1470-1480. 11p. 3 Charts, 7 Graphs.
Subjects: Auditory evoked response, Auditory cortex, Cochlear implants, Treatment of deafness, Individual differences -- Social aspects, Independent component analysis
Abstract: Auditory evoked potentials (AEPs) provide an objective measure of auditory cortical function, but AEPs from cochlear implant (CI) users are contaminated by an electrical artifact. Here, we investigated the effects of electrical artifact attenuation on AEP quality. The ability of independent component analysis (ICA) in attenuating the CI artifact while preserving the AEPs was evaluated. AEPs recovered from CI users were systematically correlated with age, demonstrating that individual differences were well preserved. CI users with high-quality AEPs were characterized by a significantly shorter duration of deafness. Finally, a simulation study revealed very high spatial correlations between original and recovered normal hearing AEPs ( r>.95) that were previously contaminated with CI artifacts. The results confirm that after ICA, good quality AEPs can be recovered, facilitating the objective, noninvasive study of auditory cortex function in CI users. [ABSTRACT FROM AUTHOR]
Copyright of Psychophysiology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites without the copyright holder's express written permission. Additionally, content may not be used with any artificial intelligence tools or machine learning technologies. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Psychology and Behavioral Sciences Collection
Full text is not displayed to guests.
Description
Abstract:Auditory evoked potentials (AEPs) provide an objective measure of auditory cortical function, but AEPs from cochlear implant (CI) users are contaminated by an electrical artifact. Here, we investigated the effects of electrical artifact attenuation on AEP quality. The ability of independent component analysis (ICA) in attenuating the CI artifact while preserving the AEPs was evaluated. AEPs recovered from CI users were systematically correlated with age, demonstrating that individual differences were well preserved. CI users with high-quality AEPs were characterized by a significantly shorter duration of deafness. Finally, a simulation study revealed very high spatial correlations between original and recovered normal hearing AEPs ( r>.95) that were previously contaminated with CI artifacts. The results confirm that after ICA, good quality AEPs can be recovered, facilitating the objective, noninvasive study of auditory cortex function in CI users. [ABSTRACT FROM AUTHOR]
ISSN:00485772
DOI:10.1111/j.1469-8986.2011.01224.x